Coloplast Luja™ Female Intermittent Catheters – Pack of 30

£99.69
In stock
Size

Coloplast Luja™ Female is a ready-to-use female intermittent urinary catheter featuring Micro-hole Zone Technology, designed to support more complete bladder emptying in one continuous flow without the need to repeatedly reposition the catheter.

Unlike conventional intermittent catheters that generally use two larger drainage eyelets near the tip, Luja Female incorporates a Micro-hole Zone with more than 50 micro-holes distributed around the catheter drainage area.

This design is intended to reduce sudden flow stops and bladder-wall suction during emptying, allowing urine to continue draining until the bladder is more completely emptied.

Luja Female also incorporates Coloplast's Triple Action Coating Technology™, a smooth hydrophilic coating designed to stay bonded, smooth and hydrated throughout catheterisation.

Available options

  • Female | 9cm | CH10 | Ref: 20051

  • Female | 9cm | CH12 | Ref: 20052

  • Female | 9cm | CH14 | Ref: 20054

  • Female | 9cm | CH16 | Ref: 20056

All variants are supplied in a pack of 30 catheters.

Key features

  • Female intermittent urinary catheter

  • Coloplast Luja™ Female

  • Micro-hole Zone Technology

  • More than 50 micro-holes across the drainage zone

  • Designed to support complete bladder emptying in one free flow

  • Designed to reduce the need to reposition the catheter during emptying

  • Helps minimise residual urine

  • Designed to reduce bladder-wall suction during drainage

  • Triple Action Coating Technology™

  • Hydrophilic catheter coating

  • Coating stays bonded, smooth and hydrated

  • Instantly ready to use

  • No separate activation water required

  • No separate lubricating gel required

  • 9cm effective catheter length

  • Tailored female catheter length

  • Micro-embossed handle for easier grip

  • Anti-roll feature

  • Discreet neutral-coloured design

  • Reclosable container

  • Recyclable product-container material where local recycling facilities permit

  • Available in CH10, CH12, CH14 and CH16

  • Sterile

  • Single use

  • Pack of 30

What is Luja Female used for?

Luja Female is designed for intermittent urinary catheterisation in women.

Intermittent catheterisation involves temporarily inserting a catheter through the urethra into the bladder to drain urine.

Once the bladder has emptied, the catheter is removed and discarded.

It may be used as part of short-term or long-term bladder management where intermittent catheterisation has been recommended by an appropriate healthcare professional.

Micro-hole Zone Technology

The defining feature of Luja Female is Coloplast's Micro-hole Zone Technology.

Conventional intermittent catheters typically drain urine through a small number of relatively large drainage eyelets.

As the bladder empties, bladder tissue can be drawn towards these openings, which may interrupt urine flow before the bladder is completely empty.

This can mean the catheter needs to be:

  • Repositioned

  • Rotated

  • Withdrawn slightly

  • Advanced again

to restart urine drainage.

Luja Female takes a different approach.

The catheter incorporates more than 50 small drainage holes distributed around the drainage zone.

This allows urine to enter through multiple openings rather than relying on only two conventional eyelets.

One free flow

Coloplast describes Luja Female as providing one free flow.

The Micro-hole Zone is designed so that urine continues to drain until the bladder is emptied, with fewer interruptions caused by bladder-wall suction.

In clinical testing cited by Coloplast, Luja Female achieved:

  • No flow stops during 87% of catheterisations

  • Less than 10ml residual urine at the first flow stop in 83% of catheterisations

Individual results may vary.

Reduced need for repositioning

With a conventional eyelet catheter, users may be taught to gradually withdraw or reposition the catheter during the final stages of bladder drainage.

Luja Female is designed to reduce this requirement.

Its Micro-hole Zone allows urine to enter the catheter at multiple points, enabling the bladder to empty without repeatedly moving or repositioning the catheter in many catheterisations.

This can provide a simpler emptying technique.

Residual urine and UTI risk

Leaving significant residual urine in the bladder after catheterisation is recognised as one of several potential risk factors associated with urinary tract infections.

Luja Female is designed to reduce the risk of UTIs by supporting more complete bladder emptying and minimising residual urine.

This does not mean that the catheter can prevent all urinary tract infections.

UTI risk is influenced by many factors, including:

  • Catheterisation technique

  • Catheterisation frequency

  • Fluid intake

  • Bladder function

  • Personal hygiene

  • Underlying medical conditions

Always follow the catheterisation routine recommended by your healthcare professional.

Reduced bladder-wall suction

As a conventional catheter drains the final amount of urine from the bladder, bladder mucosa can be drawn against the catheter eyelets.

This can:

  • Interrupt urine flow

  • Cause suction

  • Require catheter repositioning

  • Potentially cause discomfort

The multiple small openings of the Luja Micro-hole Zone are designed to substantially reduce this suction effect.

Triple Action Coating Technology™

Luja Female incorporates Coloplast's Triple Action Coating Technology™.

The hydrophilic coating is designed to:

Stay bonded

The coating remains evenly attached to the catheter surface, helping avoid areas where the coating is absent.

Stay smooth

The lubricated surface is designed to reduce friction against the urethra during insertion and withdrawal.

Stay hydrated

The catheter remains hydrated and smooth throughout catheterisation and is instantly ready to use.

No separate water or lubricating gel normally needs to be added before catheterisation.

Protection of the urethra

Women who rely on intermittent catheterisation may catheterise several times every day.

Maintaining a smooth catheter surface during both insertion and withdrawal is therefore important.

The Triple Action Coating Technology is designed to reduce friction and support gentle catheterisation of the urethra.

Instantly ready to use

Luja Female is supplied ready for immediate use.

There is no requirement to:

  • Add water

  • Burst an activation sachet

  • Wait for the catheter to hydrate

  • Apply separate lubricating gel

This can make it particularly convenient for catheterisation:

  • At home

  • At work

  • While travelling

  • In public toilets

  • Away from normal catheterisation facilities

9cm effective catheter length

All current UK Luja Female variants have an effective catheter length of:

9cm

This length is specifically tailored for female catheterisation.

It is longer than the effective catheter length of some compact female catheters, including the SpeediCath Compact Female.

The additional length can provide greater flexibility while still maintaining a compact, discreet product format.

Micro-embossed handle

Luja Female incorporates a micro-embossed handle designed to provide a secure grip.

This helps the user:

  • Hold the catheter

  • Control insertion

  • Maintain grip during catheterisation

  • Reduce unnecessary contact with the catheter tube

Always follow the handling technique described in the manufacturer's Instructions for Use.

Anti-roll feature

The product incorporates an anti-roll design.

This is intended to help prevent the catheter from rolling away when placed on a suitable surface during preparation.

This small design detail can make catheterisation easier when working with limited space.

Discreet design

Luja Female has been designed with a:

  • Neutral colour

  • Compact format

  • Discreet non-medical appearance

This can make it easier to carry in a:

  • Handbag

  • Backpack

  • Travel bag

  • Catheter kit

for use away from home.

Reclosable container

After catheterisation, the catheter can be returned to its container and reclosed.

This can provide more discreet handling and disposal when immediate disposal facilities are not conveniently available.

The catheter remains single use and must not be reused.

Recyclable container material

Coloplast states that the product container material is recyclable.

Actual recyclability depends on:

  • Local recycling facilities

  • Waste-management requirements

  • Whether the product has been used

  • Local rules regarding disposal of medical products

Product design and local waste-management arrangements may therefore limit whether the used container can actually be recycled.

Available CH sizes

Luja Female is currently available in:

  • CH10

  • CH12

  • CH14

  • CH16

CH means Charrière, also commonly called French gauge or Fr.

It describes the external diameter of the catheter.

Approximate diameters are:

  • CH10 = 3.3mm

  • CH12 = 4.0mm

  • CH14 = 4.7mm

  • CH16 = 5.3mm

A larger CH number indicates a wider catheter.

Always use the exact catheter size prescribed or recommended by your healthcare professional.

Do not change catheter diameter without appropriate advice.

How to use Luja Female

Always follow Coloplast's Instructions for Use and the catheterisation technique taught by your healthcare professional.

In general:

  1. Wash and dry your hands.

  2. Check that the individual catheter package is intact.

  3. Open the Luja Female container according to the manufacturer's instructions.

  4. Position yourself comfortably for catheterisation.

  5. Separate the labia and locate the urethral opening.

  6. Hold the catheter using the handle.

  7. Gently insert the catheter into the urethra.

  8. Continue inserting until urine begins to flow.

  9. Allow urine to drain freely.

  10. Luja's Micro-hole Zone is designed to allow drainage to continue until the bladder is emptied without repeatedly repositioning the catheter.

  11. Once urine flow has stopped, gently withdraw the catheter.

  12. Return the catheter to its container if required for discreet disposal.

  13. Dispose of the catheter appropriately.

Do not reuse the catheter.

Single use only

Each Luja Female catheter is designed for one catheterisation only.

After use:

  • Do not clean it for reuse

  • Do not reinsert it

  • Do not share the catheter

  • Dispose of it appropriately

  • Use a new sterile catheter for the next catheterisation

Important information

  • Designed for female intermittent catheterisation

  • Effective catheter length 9cm

  • Available in CH10, CH12, CH14 and CH16

  • Micro-hole Zone Technology

  • More than 50 micro-holes on CH10–CH16

  • Designed for complete bladder emptying in one free flow

  • Designed to reduce residual urine

  • Designed to reduce the need for catheter repositioning

  • Triple Action Coating Technology™

  • Hydrophilic coating

  • Instantly ready to use

  • No separate activation water normally required

  • No additional lubricating gel normally required

  • Micro-embossed grip

  • Anti-roll feature

  • Reclosable container

  • Sterile

  • Single use

  • Pack of 30

  • Use only the CH size recommended or prescribed for you

  • Do not change catheter size without appropriate healthcare advice

  • Do not use if the packaging is damaged

  • Never force the catheter against significant resistance

  • Seek healthcare advice if catheterisation becomes unusually difficult or painful

  • Seek appropriate medical advice for persistent bleeding, inability to catheterise, fever or other concerning urinary symptoms

  • Always follow Coloplast's Instructions for Use

Product details

  • Product: Coloplast Luja™ Female

  • Manufacturer: Coloplast Ltd

  • Product type: Female intermittent urinary catheter

  • Effective length: 9cm

  • Available sizes: CH10, CH12, CH14 and CH16

  • Drainage technology: Micro-hole Zone Technology

  • Number of drainage micro-holes: 50+ on CH10–CH16

  • Coating: Hydrophilic

  • Coating technology: Triple Action Coating Technology™

  • Ready to use: Yes

  • Separate activation required: No

  • Grip: Micro-embossed handle

  • Anti-roll feature: Yes

  • Reclosable: Yes

  • Sterile: Yes

  • Single use: Yes

  • Pack size: 30 catheters

  • NHS Drug Tariff: Listed

  • Classification: Intermittent urinary catheter / medical device

Order codes / variants

  • 20051 – Female | 9cm | CH10

  • 20052 – Female | 9cm | CH12

  • 20054 – Female | 9cm | CH14

  • 20056 – Female | 9cm | CH16

Pack size: 30 catheters per box

Coloplast Luja™ Female combines Micro-hole Zone Technology, a 9cm female catheter length and Triple Action Coating Technology™ to provide a ready-to-use catheter designed for simple, gentle and more complete bladder emptying.

Its 50+ micro-holes are designed to maintain urine flow as the bladder empties, helping minimise residual urine and reducing the need to repeatedly reposition the catheter during drainage.

Choose the exact CH10, CH12, CH14 or CH16 size prescribed or recommended by your healthcare professional.

Always follow Coloplast's Instructions for Use and your individual catheterisation plan.

Coloplast Luja™ Female is a ready-to-use female intermittent urinary catheter featuring Micro-hole Zone Technology, designed to support more complete bladder emptying in one continuous flow without the need to repeatedly reposition the catheter.

Unlike conventional intermittent catheters that generally use two larger drainage eyelets near the tip, Luja Female incorporates a Micro-hole Zone with more than 50 micro-holes distributed around the catheter drainage area.

This design is intended to reduce sudden flow stops and bladder-wall suction during emptying, allowing urine to continue draining until the bladder is more completely emptied.

Luja Female also incorporates Coloplast's Triple Action Coating Technology™, a smooth hydrophilic coating designed to stay bonded, smooth and hydrated throughout catheterisation.

Available options

  • Female | 9cm | CH10 | Ref: 20051

  • Female | 9cm | CH12 | Ref: 20052

  • Female | 9cm | CH14 | Ref: 20054

  • Female | 9cm | CH16 | Ref: 20056

All variants are supplied in a pack of 30 catheters.

Key features

  • Female intermittent urinary catheter

  • Coloplast Luja™ Female

  • Micro-hole Zone Technology

  • More than 50 micro-holes across the drainage zone

  • Designed to support complete bladder emptying in one free flow

  • Designed to reduce the need to reposition the catheter during emptying

  • Helps minimise residual urine

  • Designed to reduce bladder-wall suction during drainage

  • Triple Action Coating Technology™

  • Hydrophilic catheter coating

  • Coating stays bonded, smooth and hydrated

  • Instantly ready to use

  • No separate activation water required

  • No separate lubricating gel required

  • 9cm effective catheter length

  • Tailored female catheter length

  • Micro-embossed handle for easier grip

  • Anti-roll feature

  • Discreet neutral-coloured design

  • Reclosable container

  • Recyclable product-container material where local recycling facilities permit

  • Available in CH10, CH12, CH14 and CH16

  • Sterile

  • Single use

  • Pack of 30

What is Luja Female used for?

Luja Female is designed for intermittent urinary catheterisation in women.

Intermittent catheterisation involves temporarily inserting a catheter through the urethra into the bladder to drain urine.

Once the bladder has emptied, the catheter is removed and discarded.

It may be used as part of short-term or long-term bladder management where intermittent catheterisation has been recommended by an appropriate healthcare professional.

Micro-hole Zone Technology

The defining feature of Luja Female is Coloplast's Micro-hole Zone Technology.

Conventional intermittent catheters typically drain urine through a small number of relatively large drainage eyelets.

As the bladder empties, bladder tissue can be drawn towards these openings, which may interrupt urine flow before the bladder is completely empty.

This can mean the catheter needs to be:

  • Repositioned

  • Rotated

  • Withdrawn slightly

  • Advanced again

to restart urine drainage.

Luja Female takes a different approach.

The catheter incorporates more than 50 small drainage holes distributed around the drainage zone.

This allows urine to enter through multiple openings rather than relying on only two conventional eyelets.

One free flow

Coloplast describes Luja Female as providing one free flow.

The Micro-hole Zone is designed so that urine continues to drain until the bladder is emptied, with fewer interruptions caused by bladder-wall suction.

In clinical testing cited by Coloplast, Luja Female achieved:

  • No flow stops during 87% of catheterisations

  • Less than 10ml residual urine at the first flow stop in 83% of catheterisations

Individual results may vary.

Reduced need for repositioning

With a conventional eyelet catheter, users may be taught to gradually withdraw or reposition the catheter during the final stages of bladder drainage.

Luja Female is designed to reduce this requirement.

Its Micro-hole Zone allows urine to enter the catheter at multiple points, enabling the bladder to empty without repeatedly moving or repositioning the catheter in many catheterisations.

This can provide a simpler emptying technique.

Residual urine and UTI risk

Leaving significant residual urine in the bladder after catheterisation is recognised as one of several potential risk factors associated with urinary tract infections.

Luja Female is designed to reduce the risk of UTIs by supporting more complete bladder emptying and minimising residual urine.

This does not mean that the catheter can prevent all urinary tract infections.

UTI risk is influenced by many factors, including:

  • Catheterisation technique

  • Catheterisation frequency

  • Fluid intake

  • Bladder function

  • Personal hygiene

  • Underlying medical conditions

Always follow the catheterisation routine recommended by your healthcare professional.

Reduced bladder-wall suction

As a conventional catheter drains the final amount of urine from the bladder, bladder mucosa can be drawn against the catheter eyelets.

This can:

  • Interrupt urine flow

  • Cause suction

  • Require catheter repositioning

  • Potentially cause discomfort

The multiple small openings of the Luja Micro-hole Zone are designed to substantially reduce this suction effect.

Triple Action Coating Technology™

Luja Female incorporates Coloplast's Triple Action Coating Technology™.

The hydrophilic coating is designed to:

Stay bonded

The coating remains evenly attached to the catheter surface, helping avoid areas where the coating is absent.

Stay smooth

The lubricated surface is designed to reduce friction against the urethra during insertion and withdrawal.

Stay hydrated

The catheter remains hydrated and smooth throughout catheterisation and is instantly ready to use.

No separate water or lubricating gel normally needs to be added before catheterisation.

Protection of the urethra

Women who rely on intermittent catheterisation may catheterise several times every day.

Maintaining a smooth catheter surface during both insertion and withdrawal is therefore important.

The Triple Action Coating Technology is designed to reduce friction and support gentle catheterisation of the urethra.

Instantly ready to use

Luja Female is supplied ready for immediate use.

There is no requirement to:

  • Add water

  • Burst an activation sachet

  • Wait for the catheter to hydrate

  • Apply separate lubricating gel

This can make it particularly convenient for catheterisation:

  • At home

  • At work

  • While travelling

  • In public toilets

  • Away from normal catheterisation facilities

9cm effective catheter length

All current UK Luja Female variants have an effective catheter length of:

9cm

This length is specifically tailored for female catheterisation.

It is longer than the effective catheter length of some compact female catheters, including the SpeediCath Compact Female.

The additional length can provide greater flexibility while still maintaining a compact, discreet product format.

Micro-embossed handle

Luja Female incorporates a micro-embossed handle designed to provide a secure grip.

This helps the user:

  • Hold the catheter

  • Control insertion

  • Maintain grip during catheterisation

  • Reduce unnecessary contact with the catheter tube

Always follow the handling technique described in the manufacturer's Instructions for Use.

Anti-roll feature

The product incorporates an anti-roll design.

This is intended to help prevent the catheter from rolling away when placed on a suitable surface during preparation.

This small design detail can make catheterisation easier when working with limited space.

Discreet design

Luja Female has been designed with a:

  • Neutral colour

  • Compact format

  • Discreet non-medical appearance

This can make it easier to carry in a:

  • Handbag

  • Backpack

  • Travel bag

  • Catheter kit

for use away from home.

Reclosable container

After catheterisation, the catheter can be returned to its container and reclosed.

This can provide more discreet handling and disposal when immediate disposal facilities are not conveniently available.

The catheter remains single use and must not be reused.

Recyclable container material

Coloplast states that the product container material is recyclable.

Actual recyclability depends on:

  • Local recycling facilities

  • Waste-management requirements

  • Whether the product has been used

  • Local rules regarding disposal of medical products

Product design and local waste-management arrangements may therefore limit whether the used container can actually be recycled.

Available CH sizes

Luja Female is currently available in:

  • CH10

  • CH12

  • CH14

  • CH16

CH means Charrière, also commonly called French gauge or Fr.

It describes the external diameter of the catheter.

Approximate diameters are:

  • CH10 = 3.3mm

  • CH12 = 4.0mm

  • CH14 = 4.7mm

  • CH16 = 5.3mm

A larger CH number indicates a wider catheter.

Always use the exact catheter size prescribed or recommended by your healthcare professional.

Do not change catheter diameter without appropriate advice.

How to use Luja Female

Always follow Coloplast's Instructions for Use and the catheterisation technique taught by your healthcare professional.

In general:

  1. Wash and dry your hands.

  2. Check that the individual catheter package is intact.

  3. Open the Luja Female container according to the manufacturer's instructions.

  4. Position yourself comfortably for catheterisation.

  5. Separate the labia and locate the urethral opening.

  6. Hold the catheter using the handle.

  7. Gently insert the catheter into the urethra.

  8. Continue inserting until urine begins to flow.

  9. Allow urine to drain freely.

  10. Luja's Micro-hole Zone is designed to allow drainage to continue until the bladder is emptied without repeatedly repositioning the catheter.

  11. Once urine flow has stopped, gently withdraw the catheter.

  12. Return the catheter to its container if required for discreet disposal.

  13. Dispose of the catheter appropriately.

Do not reuse the catheter.

Single use only

Each Luja Female catheter is designed for one catheterisation only.

After use:

  • Do not clean it for reuse

  • Do not reinsert it

  • Do not share the catheter

  • Dispose of it appropriately

  • Use a new sterile catheter for the next catheterisation

Important information

  • Designed for female intermittent catheterisation

  • Effective catheter length 9cm

  • Available in CH10, CH12, CH14 and CH16

  • Micro-hole Zone Technology

  • More than 50 micro-holes on CH10–CH16

  • Designed for complete bladder emptying in one free flow

  • Designed to reduce residual urine

  • Designed to reduce the need for catheter repositioning

  • Triple Action Coating Technology™

  • Hydrophilic coating

  • Instantly ready to use

  • No separate activation water normally required

  • No additional lubricating gel normally required

  • Micro-embossed grip

  • Anti-roll feature

  • Reclosable container

  • Sterile

  • Single use

  • Pack of 30

  • Use only the CH size recommended or prescribed for you

  • Do not change catheter size without appropriate healthcare advice

  • Do not use if the packaging is damaged

  • Never force the catheter against significant resistance

  • Seek healthcare advice if catheterisation becomes unusually difficult or painful

  • Seek appropriate medical advice for persistent bleeding, inability to catheterise, fever or other concerning urinary symptoms

  • Always follow Coloplast's Instructions for Use

Product details

  • Product: Coloplast Luja™ Female

  • Manufacturer: Coloplast Ltd

  • Product type: Female intermittent urinary catheter

  • Effective length: 9cm

  • Available sizes: CH10, CH12, CH14 and CH16

  • Drainage technology: Micro-hole Zone Technology

  • Number of drainage micro-holes: 50+ on CH10–CH16

  • Coating: Hydrophilic

  • Coating technology: Triple Action Coating Technology™

  • Ready to use: Yes

  • Separate activation required: No

  • Grip: Micro-embossed handle

  • Anti-roll feature: Yes

  • Reclosable: Yes

  • Sterile: Yes

  • Single use: Yes

  • Pack size: 30 catheters

  • NHS Drug Tariff: Listed

  • Classification: Intermittent urinary catheter / medical device

Order codes / variants

  • 20051 – Female | 9cm | CH10

  • 20052 – Female | 9cm | CH12

  • 20054 – Female | 9cm | CH14

  • 20056 – Female | 9cm | CH16

Pack size: 30 catheters per box

Coloplast Luja™ Female combines Micro-hole Zone Technology, a 9cm female catheter length and Triple Action Coating Technology™ to provide a ready-to-use catheter designed for simple, gentle and more complete bladder emptying.

Its 50+ micro-holes are designed to maintain urine flow as the bladder empties, helping minimise residual urine and reducing the need to repeatedly reposition the catheter during drainage.

Choose the exact CH10, CH12, CH14 or CH16 size prescribed or recommended by your healthcare professional.

Always follow Coloplast's Instructions for Use and your individual catheterisation plan.