Renasys G With Soft Port Dressing Kits
RENASYS-G with Soft Port Dressing Kits are gauze-based dressing kits for use with RENASYS Negative Pressure Wound Therapy (NPWT) systems in the management of suitable acute and chronic wounds.
The kits contain an antimicrobial-impregnated gauze wound filler, transparent film and a flexible RENASYS Soft Port, together with additional wound-preparation components. The gauze conforms closely to irregular wound contours and provides an alternative to foam-based NPWT dressings.
Key features:
- Gauze dressing kit for Negative Pressure Wound Therapy (NPWT)
- For use with compatible RENASYS NPWT systems
- Contains antimicrobial-impregnated gauze
- Gauze conforms easily to irregular or complex wound shapes
- Suitable for wound cavities and undermined areas where clinically appropriate
- Includes a non-adherent wound contact layer
- Includes transparent adhesive film to create an airtight seal
- Includes RENASYS Soft Port
- Flexible, low-profile Soft Port tubing
-
Soft Port is resistant to:
- Kinking
- Twisting
- Compression
- Suitable for difficult body contours
- Includes SECURA No-Sting Barrier Film
- Includes saline for preparation of the gauze
- Includes wound-measuring ruler
- Single-use dressing components
- For use by appropriately trained healthcare professionals
- NHS prescribable in Small, Medium and Large sizes
Suitable wound types may include:
RENASYS NPWT may be used for appropriately assessed:
- Chronic wounds
- Acute wounds
- Traumatic wounds
- Sub-acute wounds
- Dehisced surgical wounds
- Pressure ulcers
- Diabetic ulcers
- Partial-thickness burns
- Flaps
- Grafts
The suitability of Negative Pressure Wound Therapy must be assessed individually by an appropriately trained healthcare professional.
Kit contents and sizes
RENASYS-G Small Dressing Kit
Contains:
- 1 × antimicrobial gauze dressing – approximately 15cm × 17cm
- 1 × RENASYS Transparent Film – 20cm × 30cm
- 1 × non-adherent gauze
- 1 × RENASYS Soft Port
- 1 × SECURA No-Sting Barrier Film Wipe
- Saline
- Paper wound ruler
Product code: 66800933
PIP code: 378-6431
NHS code: ELZ512
RENASYS-G Medium Dressing Kit
Contains:
- 2 × antimicrobial gauze dressings – approximately 15cm × 17cm each
- 1 × RENASYS Transparent Film – 20cm × 30cm
- 1 × non-adherent gauze
- 1 × RENASYS Soft Port
- 1 × SECURA No-Sting Barrier Film Wipe
- Saline
- Paper wound ruler
Product code: 66800934
PIP code: 378-6449
NHS code: ELZ513
RENASYS-G Large Dressing Kit
Contains:
- 1 × antimicrobial gauze roll – approximately 11cm × 4m
- 2 × RENASYS Transparent Films – 20cm × 30cm
- 2 × non-adherent gauze dressings
- 1 × RENASYS Soft Port
- 1 × SECURA No-Sting Barrier Film Wipe
- Saline
- Paper wound ruler
Product code: 66800935
PIP code: 378-6456
NHS code: ELZ514
RENASYS-G X-Large Dressing Kit
Contains:
- 2 × antimicrobial gauze rolls – approximately 11cm × 4m each
- 3 × RENASYS Transparent Films – 20cm × 30cm
- 4 × non-adherent gauze dressings
- 1 × RENASYS Soft Port
- 2 × SECURA No-Sting Barrier Film Wipes
- 2 × saline units
- Paper wound ruler
Product code: 66800936
NHS code: ELZ535
No standard UK PIP code is currently listed for the X-Large version.
How RENASYS-G works:
The antimicrobial gauze is placed into the wound and covered with an airtight transparent film.
The RENASYS Soft Port is positioned over an opening made in the transparent film and connected to a compatible RENASYS NPWT pump.
The prescribed negative pressure:
- Draws wound exudate away from the wound
- Helps remove excess fluid
- Helps maintain a controlled wound environment
- Supports wound contraction and granulation where clinically appropriate
- Transfers exudate through the tubing into the collection canister
The antimicrobial gauze provides a conformable wound filler while the Soft Port transfers the negative pressure from the therapy unit to the wound.
How to apply:
RENASYS-G Dressing Kits should be applied by an appropriately trained healthcare professional according to the manufacturer's Instructions for Use and the patient's NPWT treatment plan.
In general:
- Assess and prepare the wound according to local wound-care protocol.
- Clean the wound as clinically appropriate.
- Protect sensitive structures with the supplied non-adherent contact layer where required.
- Moisten the antimicrobial gauze with the supplied saline according to the application instructions.
- Gently place the gauze into the wound cavity.
- Ensure the gauze contacts the wound surfaces without excessive packing or compression.
- Record the number of pieces of gauze placed into the wound.
- Cover the wound completely with RENASYS Transparent Film to create an airtight seal.
- Create the required opening in the transparent film over the wound filler.
- Position the RENASYS Soft Port over the opening.
- Connect the Soft Port to the compatible RENASYS canister and NPWT system.
- Start therapy at the pressure prescribed by the treating healthcare professional.
- Confirm that the dressing is sealed and that negative pressure is being maintained.
Important gauze-counting precaution:
Every piece of gauze placed into the wound must be accounted for and removed at each dressing change.
Do not leave gauze fragments in the wound.
Documenting the number of gauze pieces used is particularly important in deep, undermined or complex wounds.
RENASYS Soft Port:
The Soft Port provides the connection between the sealed dressing and the NPWT system.
Its design features:
- Soft, flexible tubing
- Compression-resistant construction
- Low-profile connection
- Resistance to kinking and twisting
-
Conformability around awkward anatomical areas such as:
- Heels
- Knees
- Elbows
- Hips
The Soft Port may reduce the need for complicated bridging techniques in appropriate wounds.
Dressing changes:
The frequency of dressing changes must be determined according to:
- Wound condition
- Level and type of exudate
- Presence or risk of infection
- Integrity of the dressing seal
- Patient condition
- Clinical judgement
Infected wounds or wounds producing heavy or problematic exudate may require more frequent dressing changes.
Do not leave a RENASYS dressing in place beyond the interval specified in the current Instructions for Use or the patient's prescribed wound-care plan.
Important information:
RENASYS-G Dressing Kits are intended for use as part of a RENASYS Negative Pressure Wound Therapy system.
They do not provide negative-pressure therapy when used independently.
NPWT must be prescribed and monitored by an appropriately trained healthcare professional.
Do not use RENASYS NPWT in the presence of:
- Untreated osteomyelitis
- Necrotic tissue with eschar present
- Exposed arteries or veins
- Exposed organs
- Exposed nerves
- Exposed anastomotic sites
- Non-enteric and unexplored fistulas
- Malignancy within the wound, except where specifically considered appropriate for palliative treatment
Necrotic tissue and eschar should be appropriately debrided before NPWT is considered.
Do not place the gauze dressing directly against unprotected:
- Blood vessels
- Organs
- Nerves
- Anastomotic sites
- Other vulnerable structures
Use an appropriate non-adherent protective interface where clinically indicated.
Bleeding warning:
Excessive bleeding is a potentially serious and life-threatening complication of NPWT.
Particular care is required in patients:
- At increased risk of bleeding
- Taking anticoagulant or antiplatelet medicines
- With vascular grafts
- With fragile blood vessels
- Following recent surgery
- Where haemostasis may not be secure
Regularly inspect:
- The Soft Port
- Tubing
- Canister
- Wound dressing
for evidence of blood.
If sudden or significant bleeding occurs, manage therapy immediately according to the patient's NPWT emergency plan and obtain urgent medical assessment.
Infection:
NPWT does not replace appropriate treatment of wound infection.
Monitor for:
- Increasing redness
- Increasing swelling
- Increasing pain
- Purulent discharge
- Offensive odour
- Fever
- Deterioration of the wound
Seek clinical review if infection or sepsis is suspected.
Single-use information:
RENASYS-G dressing components are intended for single use.
Do not:
- Reuse the wound filler
- Reuse the Soft Port
- Re-sterilise components
- Use components if sterile packaging is damaged
- Modify the dressing components
- Mix incompatible NPWT components
Product type: Negative Pressure Wound Therapy Gauze Dressing Kit
Therapy: NPWT / Topical Negative Pressure Therapy
Wound filler: Antimicrobial-impregnated gauze
Wound interface: Non-adherent gauze supplied
Connection: RENASYS Soft Port
Seal: RENASYS Transparent Film
Single use: Yes
Pack size: 1 complete dressing kit
Current NHS-prescribable sizes:
- Small
- Medium
- Large
Additional manufacturer size:
- X-Large
Product codes:
- Small – 66800933
- Medium – 66800934
- Large – 66800935
- X-Large – 66800936
PIP codes:
- Small – 378-6431
- Medium – 378-6449
- Large – 378-6456
NHS codes:
- Small – ELZ512
- Medium – ELZ513
- Large – ELZ514
- X-Large – ELZ535
Manufacturer: Smith & Nephew
RENASYS-G with Soft Port Dressing Kits should only be used as part of an appropriately prescribed RENASYS Negative Pressure Wound Therapy system and in accordance with the manufacturer's Instructions for Use and the patient's individual wound-care plan.
RENASYS-G with Soft Port Dressing Kits are gauze-based dressing kits for use with RENASYS Negative Pressure Wound Therapy (NPWT) systems in the management of suitable acute and chronic wounds.
The kits contain an antimicrobial-impregnated gauze wound filler, transparent film and a flexible RENASYS Soft Port, together with additional wound-preparation components. The gauze conforms closely to irregular wound contours and provides an alternative to foam-based NPWT dressings.
Key features:
- Gauze dressing kit for Negative Pressure Wound Therapy (NPWT)
- For use with compatible RENASYS NPWT systems
- Contains antimicrobial-impregnated gauze
- Gauze conforms easily to irregular or complex wound shapes
- Suitable for wound cavities and undermined areas where clinically appropriate
- Includes a non-adherent wound contact layer
- Includes transparent adhesive film to create an airtight seal
- Includes RENASYS Soft Port
- Flexible, low-profile Soft Port tubing
-
Soft Port is resistant to:
- Kinking
- Twisting
- Compression
- Suitable for difficult body contours
- Includes SECURA No-Sting Barrier Film
- Includes saline for preparation of the gauze
- Includes wound-measuring ruler
- Single-use dressing components
- For use by appropriately trained healthcare professionals
- NHS prescribable in Small, Medium and Large sizes
Suitable wound types may include:
RENASYS NPWT may be used for appropriately assessed:
- Chronic wounds
- Acute wounds
- Traumatic wounds
- Sub-acute wounds
- Dehisced surgical wounds
- Pressure ulcers
- Diabetic ulcers
- Partial-thickness burns
- Flaps
- Grafts
The suitability of Negative Pressure Wound Therapy must be assessed individually by an appropriately trained healthcare professional.
Kit contents and sizes
RENASYS-G Small Dressing Kit
Contains:
- 1 × antimicrobial gauze dressing – approximately 15cm × 17cm
- 1 × RENASYS Transparent Film – 20cm × 30cm
- 1 × non-adherent gauze
- 1 × RENASYS Soft Port
- 1 × SECURA No-Sting Barrier Film Wipe
- Saline
- Paper wound ruler
Product code: 66800933
PIP code: 378-6431
NHS code: ELZ512
RENASYS-G Medium Dressing Kit
Contains:
- 2 × antimicrobial gauze dressings – approximately 15cm × 17cm each
- 1 × RENASYS Transparent Film – 20cm × 30cm
- 1 × non-adherent gauze
- 1 × RENASYS Soft Port
- 1 × SECURA No-Sting Barrier Film Wipe
- Saline
- Paper wound ruler
Product code: 66800934
PIP code: 378-6449
NHS code: ELZ513
RENASYS-G Large Dressing Kit
Contains:
- 1 × antimicrobial gauze roll – approximately 11cm × 4m
- 2 × RENASYS Transparent Films – 20cm × 30cm
- 2 × non-adherent gauze dressings
- 1 × RENASYS Soft Port
- 1 × SECURA No-Sting Barrier Film Wipe
- Saline
- Paper wound ruler
Product code: 66800935
PIP code: 378-6456
NHS code: ELZ514
RENASYS-G X-Large Dressing Kit
Contains:
- 2 × antimicrobial gauze rolls – approximately 11cm × 4m each
- 3 × RENASYS Transparent Films – 20cm × 30cm
- 4 × non-adherent gauze dressings
- 1 × RENASYS Soft Port
- 2 × SECURA No-Sting Barrier Film Wipes
- 2 × saline units
- Paper wound ruler
Product code: 66800936
NHS code: ELZ535
No standard UK PIP code is currently listed for the X-Large version.
How RENASYS-G works:
The antimicrobial gauze is placed into the wound and covered with an airtight transparent film.
The RENASYS Soft Port is positioned over an opening made in the transparent film and connected to a compatible RENASYS NPWT pump.
The prescribed negative pressure:
- Draws wound exudate away from the wound
- Helps remove excess fluid
- Helps maintain a controlled wound environment
- Supports wound contraction and granulation where clinically appropriate
- Transfers exudate through the tubing into the collection canister
The antimicrobial gauze provides a conformable wound filler while the Soft Port transfers the negative pressure from the therapy unit to the wound.
How to apply:
RENASYS-G Dressing Kits should be applied by an appropriately trained healthcare professional according to the manufacturer's Instructions for Use and the patient's NPWT treatment plan.
In general:
- Assess and prepare the wound according to local wound-care protocol.
- Clean the wound as clinically appropriate.
- Protect sensitive structures with the supplied non-adherent contact layer where required.
- Moisten the antimicrobial gauze with the supplied saline according to the application instructions.
- Gently place the gauze into the wound cavity.
- Ensure the gauze contacts the wound surfaces without excessive packing or compression.
- Record the number of pieces of gauze placed into the wound.
- Cover the wound completely with RENASYS Transparent Film to create an airtight seal.
- Create the required opening in the transparent film over the wound filler.
- Position the RENASYS Soft Port over the opening.
- Connect the Soft Port to the compatible RENASYS canister and NPWT system.
- Start therapy at the pressure prescribed by the treating healthcare professional.
- Confirm that the dressing is sealed and that negative pressure is being maintained.
Important gauze-counting precaution:
Every piece of gauze placed into the wound must be accounted for and removed at each dressing change.
Do not leave gauze fragments in the wound.
Documenting the number of gauze pieces used is particularly important in deep, undermined or complex wounds.
RENASYS Soft Port:
The Soft Port provides the connection between the sealed dressing and the NPWT system.
Its design features:
- Soft, flexible tubing
- Compression-resistant construction
- Low-profile connection
- Resistance to kinking and twisting
-
Conformability around awkward anatomical areas such as:
- Heels
- Knees
- Elbows
- Hips
The Soft Port may reduce the need for complicated bridging techniques in appropriate wounds.
Dressing changes:
The frequency of dressing changes must be determined according to:
- Wound condition
- Level and type of exudate
- Presence or risk of infection
- Integrity of the dressing seal
- Patient condition
- Clinical judgement
Infected wounds or wounds producing heavy or problematic exudate may require more frequent dressing changes.
Do not leave a RENASYS dressing in place beyond the interval specified in the current Instructions for Use or the patient's prescribed wound-care plan.
Important information:
RENASYS-G Dressing Kits are intended for use as part of a RENASYS Negative Pressure Wound Therapy system.
They do not provide negative-pressure therapy when used independently.
NPWT must be prescribed and monitored by an appropriately trained healthcare professional.
Do not use RENASYS NPWT in the presence of:
- Untreated osteomyelitis
- Necrotic tissue with eschar present
- Exposed arteries or veins
- Exposed organs
- Exposed nerves
- Exposed anastomotic sites
- Non-enteric and unexplored fistulas
- Malignancy within the wound, except where specifically considered appropriate for palliative treatment
Necrotic tissue and eschar should be appropriately debrided before NPWT is considered.
Do not place the gauze dressing directly against unprotected:
- Blood vessels
- Organs
- Nerves
- Anastomotic sites
- Other vulnerable structures
Use an appropriate non-adherent protective interface where clinically indicated.
Bleeding warning:
Excessive bleeding is a potentially serious and life-threatening complication of NPWT.
Particular care is required in patients:
- At increased risk of bleeding
- Taking anticoagulant or antiplatelet medicines
- With vascular grafts
- With fragile blood vessels
- Following recent surgery
- Where haemostasis may not be secure
Regularly inspect:
- The Soft Port
- Tubing
- Canister
- Wound dressing
for evidence of blood.
If sudden or significant bleeding occurs, manage therapy immediately according to the patient's NPWT emergency plan and obtain urgent medical assessment.
Infection:
NPWT does not replace appropriate treatment of wound infection.
Monitor for:
- Increasing redness
- Increasing swelling
- Increasing pain
- Purulent discharge
- Offensive odour
- Fever
- Deterioration of the wound
Seek clinical review if infection or sepsis is suspected.
Single-use information:
RENASYS-G dressing components are intended for single use.
Do not:
- Reuse the wound filler
- Reuse the Soft Port
- Re-sterilise components
- Use components if sterile packaging is damaged
- Modify the dressing components
- Mix incompatible NPWT components
Product type: Negative Pressure Wound Therapy Gauze Dressing Kit
Therapy: NPWT / Topical Negative Pressure Therapy
Wound filler: Antimicrobial-impregnated gauze
Wound interface: Non-adherent gauze supplied
Connection: RENASYS Soft Port
Seal: RENASYS Transparent Film
Single use: Yes
Pack size: 1 complete dressing kit
Current NHS-prescribable sizes:
- Small
- Medium
- Large
Additional manufacturer size:
- X-Large
Product codes:
- Small – 66800933
- Medium – 66800934
- Large – 66800935
- X-Large – 66800936
PIP codes:
- Small – 378-6431
- Medium – 378-6449
- Large – 378-6456
NHS codes:
- Small – ELZ512
- Medium – ELZ513
- Large – ELZ514
- X-Large – ELZ535
Manufacturer: Smith & Nephew
RENASYS-G with Soft Port Dressing Kits should only be used as part of an appropriately prescribed RENASYS Negative Pressure Wound Therapy system and in accordance with the manufacturer's Instructions for Use and the patient's individual wound-care plan.
