Renasys Y Connector 66800971

£6.35
In stock

RENASYS Y Connector is a single-use accessory for RENASYS Negative Pressure Wound Therapy (NPWT) systems, designed to connect two RENASYS Soft Ports and/or drains to a single compatible RENASYS pump.

It can be used where two therapy connections are required for one wound, or where two separate appropriate wounds are being treated simultaneously using one NPWT device.

Key features:

  • Accessory for RENASYS Negative Pressure Wound Therapy
  • Connects two RENASYS Soft Ports and/or drains
  • Allows two therapy lines to connect to one compatible NPWT pump
  • Can be used with:
    • Two ports on a single wound
    • Two separate wounds where clinically appropriate
  • Compatible with selected RENASYS dressing and drainage systems
  • Quick-connect design for connection to the RENASYS therapy circuit
  • Single-use medical device
  • Supplied individually
  • For use by appropriately trained healthcare professionals

Compatible RENASYS products include:

The RENASYS Y Connector can be used with appropriate RENASYS components including:

  • RENASYS-F Foam Dressing Kits with Soft Port
  • RENASYS-G Gauze Dressing Kits with Soft Port
  • RENASYS Soft Port
  • RENASYS Drain Kits
  • Selected RENASYS abdominal dressing applications when used in an approved single-wound configuration

It is designed for use with compatible RENASYS NPWT pumps according to the Instructions for Use for the individual therapy system.

How it works:

The Y Connector has:

  • Two patient-side branches for connection to RENASYS Soft Ports and/or drains
  • One main therapy connection leading to the NPWT pump and canister system

This allows negative pressure from one compatible RENASYS pump to be distributed through two therapy connections.

When used with two separate wounds, both wounds are treated using the same therapy pressure setting.

For this reason, wounds requiring substantially different negative-pressure settings should not normally be connected using one Y Connector.

How to use:

The RENASYS Y Connector should be set up by an appropriately trained healthcare professional as part of a prescribed NPWT treatment plan.

In general:

  1. Prepare the wound or wounds and apply the appropriate RENASYS dressing systems according to their Instructions for Use.
  2. Prepare the compatible RENASYS NPWT pump and canister.
  3. Connect the main channel of the Y Connector to the canister tubing.
  4. Connect each of the two branches to the appropriate RENASYS Soft Port and/or drain.
  5. Ensure all connections are secure.
  6. Start therapy using the pressure setting prescribed by the treating healthcare professional.
  7. Check each dressing individually to confirm that negative pressure is being applied correctly and that the dressing is appropriately compressed.
  8. Regularly monitor both wounds and the complete therapy circuit.

Always follow the current Smith+Nephew Instructions for Use for the pump, dressing and Y Connector.

Use with two wounds:

When treating two separate wounds with one Y Connector:

  • Both wounds must be suitable for the same negative-pressure setting
  • Both wound dressings should be checked regularly to ensure therapy is being delivered
  • The same type of dressing kit should normally be used for both wounds
  • Each wound must be assessed individually throughout treatment

If both wounds require particularly close independent monitoring, separate NPWT devices or an alternative dressing configuration may be more appropriate.

Important information:

RENASYS Y Connector is an NPWT system accessory and does not provide negative-pressure therapy when used on its own.

It must be used with:

  • A compatible RENASYS NPWT pump
  • Appropriate RENASYS wound dressings
  • A suitable canister and therapy circuit where required

Therapy must be prescribed and supervised by an appropriately trained healthcare professional.

Do not connect an infected wound and a non-infected wound using the same Y Connector.

This could create a risk of cross-contamination between the two wound systems.

Do not use a two-wound Y Connector configuration for:

  • Flaps
  • Grafts
  • Open abdominal wounds

These applications may only be suitable in specifically approved single-wound configurations according to the RENASYS Instructions for Use.

Do not use a Y Connector to connect two wounds that require different negative-pressure settings.

Monitoring:

When two separate wounds are connected to one pump:

  • Check both dressings regularly
  • Confirm that each dressing remains compressed
  • Check for leaks
  • Check tubing for blockage or kinking
  • Monitor wound exudate
  • Monitor for signs of bleeding or infection
  • Ensure therapy remains active at both wound sites

A pump alarm may not necessarily identify which branch or wound is responsible for a leak or blockage, so both wound systems should be checked individually.

Bleeding and infection:

Negative Pressure Wound Therapy can be associated with serious complications if used inappropriately.

Seek urgent clinical assessment if there is:

  • Sudden or significant bleeding
  • Rapidly increasing blood in the tubing or canister
  • Significant deterioration of either wound
  • Signs of spreading infection
  • Fever or suspected sepsis

NPWT does not replace appropriate treatment of wound infection.

Single-use information:

The RENASYS Y Connector is intended for single-patient use.

Do not:

  • Reuse the connector on another patient
  • Use a damaged connector
  • Use if the packaging has been compromised
  • Modify the connector
  • Connect incompatible devices or tubing

Smith+Nephew clinical guidance advises that the Y Connector should be changed once a week or whenever the canister is changed, whichever occurs first, unless clinical circumstances or the current Instructions for Use require more frequent replacement.

Product type: Negative Pressure Wound Therapy Accessory / Y Connector

Therapy: NPWT / Topical Negative Pressure Therapy

Connections: 2 patient-side connections to 1 therapy line

Compatible connections: RENASYS Soft Ports and/or drains

Application: One wound with two ports or two appropriate wounds

Single use: Yes

Pack size: 1 Y Connector

Manufacturer product code: 66800971

PIP code: 381-2807

NHS code: ELZ518

Case quantity: 10 individually packed Y Connectors

Manufacturer: Smith+Nephew

RENASYS Y Connector should only be used as part of an appropriately prescribed RENASYS Negative Pressure Wound Therapy system and in accordance with the manufacturer's Instructions for Use.

RENASYS Y Connector is a single-use accessory for RENASYS Negative Pressure Wound Therapy (NPWT) systems, designed to connect two RENASYS Soft Ports and/or drains to a single compatible RENASYS pump.

It can be used where two therapy connections are required for one wound, or where two separate appropriate wounds are being treated simultaneously using one NPWT device.

Key features:

  • Accessory for RENASYS Negative Pressure Wound Therapy
  • Connects two RENASYS Soft Ports and/or drains
  • Allows two therapy lines to connect to one compatible NPWT pump
  • Can be used with:
    • Two ports on a single wound
    • Two separate wounds where clinically appropriate
  • Compatible with selected RENASYS dressing and drainage systems
  • Quick-connect design for connection to the RENASYS therapy circuit
  • Single-use medical device
  • Supplied individually
  • For use by appropriately trained healthcare professionals

Compatible RENASYS products include:

The RENASYS Y Connector can be used with appropriate RENASYS components including:

  • RENASYS-F Foam Dressing Kits with Soft Port
  • RENASYS-G Gauze Dressing Kits with Soft Port
  • RENASYS Soft Port
  • RENASYS Drain Kits
  • Selected RENASYS abdominal dressing applications when used in an approved single-wound configuration

It is designed for use with compatible RENASYS NPWT pumps according to the Instructions for Use for the individual therapy system.

How it works:

The Y Connector has:

  • Two patient-side branches for connection to RENASYS Soft Ports and/or drains
  • One main therapy connection leading to the NPWT pump and canister system

This allows negative pressure from one compatible RENASYS pump to be distributed through two therapy connections.

When used with two separate wounds, both wounds are treated using the same therapy pressure setting.

For this reason, wounds requiring substantially different negative-pressure settings should not normally be connected using one Y Connector.

How to use:

The RENASYS Y Connector should be set up by an appropriately trained healthcare professional as part of a prescribed NPWT treatment plan.

In general:

  1. Prepare the wound or wounds and apply the appropriate RENASYS dressing systems according to their Instructions for Use.
  2. Prepare the compatible RENASYS NPWT pump and canister.
  3. Connect the main channel of the Y Connector to the canister tubing.
  4. Connect each of the two branches to the appropriate RENASYS Soft Port and/or drain.
  5. Ensure all connections are secure.
  6. Start therapy using the pressure setting prescribed by the treating healthcare professional.
  7. Check each dressing individually to confirm that negative pressure is being applied correctly and that the dressing is appropriately compressed.
  8. Regularly monitor both wounds and the complete therapy circuit.

Always follow the current Smith+Nephew Instructions for Use for the pump, dressing and Y Connector.

Use with two wounds:

When treating two separate wounds with one Y Connector:

  • Both wounds must be suitable for the same negative-pressure setting
  • Both wound dressings should be checked regularly to ensure therapy is being delivered
  • The same type of dressing kit should normally be used for both wounds
  • Each wound must be assessed individually throughout treatment

If both wounds require particularly close independent monitoring, separate NPWT devices or an alternative dressing configuration may be more appropriate.

Important information:

RENASYS Y Connector is an NPWT system accessory and does not provide negative-pressure therapy when used on its own.

It must be used with:

  • A compatible RENASYS NPWT pump
  • Appropriate RENASYS wound dressings
  • A suitable canister and therapy circuit where required

Therapy must be prescribed and supervised by an appropriately trained healthcare professional.

Do not connect an infected wound and a non-infected wound using the same Y Connector.

This could create a risk of cross-contamination between the two wound systems.

Do not use a two-wound Y Connector configuration for:

  • Flaps
  • Grafts
  • Open abdominal wounds

These applications may only be suitable in specifically approved single-wound configurations according to the RENASYS Instructions for Use.

Do not use a Y Connector to connect two wounds that require different negative-pressure settings.

Monitoring:

When two separate wounds are connected to one pump:

  • Check both dressings regularly
  • Confirm that each dressing remains compressed
  • Check for leaks
  • Check tubing for blockage or kinking
  • Monitor wound exudate
  • Monitor for signs of bleeding or infection
  • Ensure therapy remains active at both wound sites

A pump alarm may not necessarily identify which branch or wound is responsible for a leak or blockage, so both wound systems should be checked individually.

Bleeding and infection:

Negative Pressure Wound Therapy can be associated with serious complications if used inappropriately.

Seek urgent clinical assessment if there is:

  • Sudden or significant bleeding
  • Rapidly increasing blood in the tubing or canister
  • Significant deterioration of either wound
  • Signs of spreading infection
  • Fever or suspected sepsis

NPWT does not replace appropriate treatment of wound infection.

Single-use information:

The RENASYS Y Connector is intended for single-patient use.

Do not:

  • Reuse the connector on another patient
  • Use a damaged connector
  • Use if the packaging has been compromised
  • Modify the connector
  • Connect incompatible devices or tubing

Smith+Nephew clinical guidance advises that the Y Connector should be changed once a week or whenever the canister is changed, whichever occurs first, unless clinical circumstances or the current Instructions for Use require more frequent replacement.

Product type: Negative Pressure Wound Therapy Accessory / Y Connector

Therapy: NPWT / Topical Negative Pressure Therapy

Connections: 2 patient-side connections to 1 therapy line

Compatible connections: RENASYS Soft Ports and/or drains

Application: One wound with two ports or two appropriate wounds

Single use: Yes

Pack size: 1 Y Connector

Manufacturer product code: 66800971

PIP code: 381-2807

NHS code: ELZ518

Case quantity: 10 individually packed Y Connectors

Manufacturer: Smith+Nephew

RENASYS Y Connector should only be used as part of an appropriately prescribed RENASYS Negative Pressure Wound Therapy system and in accordance with the manufacturer's Instructions for Use.