Coloplast Conveen® Contour Leg Bag – 600ml, 45cm Adjustable Tube – Pack of 10 (Ref: 5170)

£55.95
10 in stock

Coloplast Conveen® Contour 5170 is a 600ml urinary leg drainage bag with a 45cm adjustable inlet tube, designed for discreet daytime urine collection.

It can be used with a suitable urinary sheath or permanent urinary catheter, providing a practical urine collection system for people requiring continuous drainage during the day.

Unlike the fixed-length sterile Conveen® Contour variants, reference 5170 is the non-sterile adjustable-tube version. Its inlet tubing can be adjusted to provide a more individualised distance between the catheter or sheath connection and the drainage bag.

The Conveen® Contour design incorporates multiple internal chambers, which help distribute urine throughout the bag instead of allowing it to collect in a single compartment. This helps reduce movement and sloshing of urine and allows the bag to remain flatter and more discreet against the leg.

A compact clamp-style drainage outlet allows repeated emptying, while the soft non-woven backing provides a comfortable surface against the skin and helps reduce noise during movement.

Key features:

  • 600ml urinary leg drainage bag

  • Coloplast reference 5170

  • 45cm adjustable inlet tube

  • Tube can be adjusted to suit individual positioning requirements

  • Non-sterile version

  • Designed for daytime urinary drainage

  • Suitable for use with a compatible urinary sheath

  • Suitable for use with a permanent urinary catheter

  • Multiple internal chambers

  • Helps distribute urine throughout the bag

  • Helps reduce movement and sloshing of urine

  • Helps maintain a flatter profile against the leg

  • Designed for discreet wear beneath clothing

  • Compact clamp-style drainage outlet

  • Outlet design makes it easy to see whether the clamp is open or closed

  • Soft non-woven backing

  • Helps improve comfort against the leg

  • Helps reduce noise during movement

  • Drainable for repeated emptying during use

  • Pack of 10

Suitable for:

  • Daytime urinary drainage

  • Users of compatible male urinary sheaths

  • Permanent urinary catheter users

  • Ambulatory catheter users

  • Users requiring a 600ml capacity

  • Users requiring an adjustable inlet tube

  • Users who need greater flexibility in leg-bag positioning

  • Users who prefer a discreet multi-chamber drainage bag

  • Users who do not specifically require a sterile leg-bag version

600ml capacity

Conveen® Contour 5170 provides a 600ml urine collection capacity.

This offers a practical compromise between sufficient daytime urine capacity and a relatively discreet profile underneath clothing.

The bag should be emptied regularly and before it becomes excessively full or heavy.

Allowing a leg bag to become too full can:

  • Increase pulling on the catheter or urinary sheath

  • Make the bag more noticeable

  • Increase pressure on the leg

  • Place additional strain on the fixation system

  • Reduce comfort during walking and normal movement

45cm adjustable inlet tube

Reference 5170 has a 45cm inlet tube that can be adjusted to suit the required leg-bag position.

This distinguishes it from the fixed-tube Conveen® Contour options.

An adjustable tube allows the drainage system to be adapted according to:

  • Where the leg bag is positioned

  • The location of the catheter or sheath connection

  • The user's height and anatomy

  • Clothing

  • Mobility

  • Personal preference

The tube should be adjusted according to the manufacturer's instructions.

Once positioned, the drainage pathway should remain free from:

  • Kinks

  • Twisting

  • Compression

  • Excessive loops

  • Pulling on the catheter or urinary sheath

  • Obstruction beneath clothing

When used with a urinary catheter, the bag should remain below bladder level to allow effective gravity drainage.

Adjustable tube or fixed tube?

The Conveen® Contour range includes both adjustable and fixed inlet-tube versions.

5170 – Adjustable tube

The 45cm tube can be adjusted to provide a more individualised position of the drainage bag on the leg.

This may be useful where a standard fixed tube length does not provide the preferred positioning.

5172 – Fixed 5cm tube

A very short fixed inlet tube for users requiring the bag close to the catheter or sheath connection.

5173 – Fixed 30cm tube

A medium-length fixed tube for conventional leg positioning.

5175 – Fixed 45cm tube

A longer fixed tube combined with a larger 800ml capacity.

Multiple-chamber design

Conveen® Contour incorporates multiple internal chambers or channels.

Instead of collected urine accumulating in one large compartment, the chambers help distribute it across the drainage bag.

This can help:

  • Distribute urine more evenly

  • Reduce excessive bulging in one area

  • Keep the drainage bag flatter against the leg

  • Reduce movement of urine

  • Reduce noticeable sloshing

  • Improve discretion beneath clothing

  • Improve comfort during walking and movement

The multi-chamber construction is one of the principal features of the Conveen® Contour range.

Clamp drainage outlet

Conveen® Contour incorporates a compact clamp-style outlet for emptying the urine bag.

The clamp provides a straightforward opening and closing mechanism and allows the user to visually check whether the drainage outlet is correctly closed.

The small outlet design also helps minimise bulk at the bottom of the bag.

After emptying, always ensure the clamp is completely closed before repositioning the bag.

Soft non-woven backing

The skin-facing side of the Conveen® Contour bag incorporates a soft non-woven backing material.

This provides a more comfortable surface between the drainage bag and the leg and helps:

  • Improve comfort during prolonged wear

  • Allow the skin to breathe

  • Reduce noise during movement

  • Improve discretion underneath clothing

The skin underneath and around the bag should still be checked regularly for redness, moisture, pressure or irritation.

Using with a urinary catheter

Conveen® Contour 5170 can be used with an appropriate permanent urinary catheter.

When connecting the leg bag:

  • Wash and dry your hands

  • Ensure the drainage clamp is completely closed

  • Adjust the tube according to the manufacturer's instructions if required

  • Avoid touching the connection surfaces unnecessarily

  • Connect the leg bag securely to the catheter

  • Position the bag below bladder level

  • Ensure the tubing follows a natural route

  • Check that there are no kinks or obstructions

  • Confirm that urine is draining freely

Avoid disconnecting an established catheter drainage system unnecessarily.

Using with a urinary sheath

Conveen® Contour can also be connected to an appropriate male urinary sheath, including compatible Conveen® sheath systems.

The sheath directs urine through the connecting tubing and into the leg bag.

Correct sheath sizing and application are important to reduce the risk of:

  • Leakage

  • Skin irritation

  • Sheath detachment

  • Restriction

  • Poor drainage

Always follow the manufacturer's instructions supplied with the urinary sheath.

Positioning the leg bag

Secure the bag appropriately against the leg using a suitable leg-bag fixation system.

The adjustable inlet tube allows greater flexibility in positioning than a fixed-length tube.

Ensure that:

  • The tube has been adjusted correctly

  • The bag is comfortable during walking and sitting

  • The tubing is not kinked or compressed

  • There is no excessive tension on the catheter or sheath

  • The bag remains adequately supported as it fills

  • The drainage outlet remains easy to access

  • The bag remains below bladder level when used with a catheter

Avoid securing the bag so tightly that circulation is restricted.

Directions:

Wash and dry your hands thoroughly.

Remove the Conveen® Contour bag from its packaging.

Ensure the clamp drainage outlet is securely closed.

Adjust the inlet tube to the required length according to the manufacturer's instructions.

Position and secure the bag appropriately against the leg.

Connect the inlet securely to the urinary catheter or compatible urinary sheath.

Arrange the tubing so that it is free from kinks, compression and unnecessary tension.

When used with a urinary catheter, ensure the drainage bag remains below bladder level.

Check that urine is able to drain freely into the bag.

Emptying the bag:

Empty the leg bag regularly and before it becomes excessively full.

Wash your hands.

Position the outlet over a toilet or suitable receptacle.

Open the clamp outlet.

Allow the urine to drain completely.

Avoid allowing the drainage outlet to touch the toilet or receptacle.

Close the clamp securely.

Check visually that the outlet is fully closed.

Reposition the bag as required.

Wash your hands after handling the drainage system.

Changing the leg bag:

Replace the bag according to the manufacturer's instructions and the individual's catheter or continence-care plan.

Change the drainage bag sooner if:

  • The bag becomes damaged

  • Leakage develops

  • The clamp no longer closes securely

  • Tubing becomes damaged or obstructed

  • The connection becomes insecure

  • The drainage system becomes contaminated

  • A healthcare professional advises replacement

Avoid unnecessary disconnection of an established catheter drainage system.

Important information:

  • For urinary drainage

  • Reference 5170

  • 600ml capacity

  • 45cm adjustable inlet tube

  • Non-sterile

  • Do not confuse with sterile fixed-tube references 5172, 5173 or 5175

  • Multiple-chamber design

  • Clamp-style drainage outlet

  • Soft non-woven backing

  • Suitable for use with compatible urinary sheaths

  • Suitable for use with permanent urinary catheters

  • Adjust the inlet tube only according to the manufacturer's instructions

  • Keep the drainage bag below bladder level when connected to a catheter

  • Ensure tubing remains free from kinks and obstruction

  • Empty the bag regularly

  • Do not allow the bag to become excessively full or heavy

  • Avoid pulling or excessive tension on the catheter or urinary sheath

  • Secure the bag appropriately against the leg

  • Maintain appropriate hand hygiene

  • Avoid unnecessary disconnection of a catheter drainage system

  • Ensure the clamp is completely closed after emptying

  • Check regularly that urine is draining freely

  • Check the skin for redness, pressure or irritation

  • Seek clinical advice if urine unexpectedly stops draining

  • Seek appropriate healthcare advice for persistent leakage, catheter-associated pain, significant blood in the urine, fever, lower abdominal or flank pain, or other symptoms suggesting urinary infection or catheter complications

  • Always follow the manufacturer's instructions for use

Product details:

  • Product: Conveen® Contour Leg Bag

  • Manufacturer: Coloplast Ltd

  • Reference / order code: 5170

  • Product type: Urinary leg drainage bag

  • Capacity: 600ml

  • Inlet tube: 45cm adjustable tube

  • Tube type: Adjustable

  • Outlet: Clamp

  • Multiple chambers: Yes

  • Soft non-woven backing: Yes

  • Sterile: No

  • Drainable: Yes

  • Suitable for urinary sheaths: Yes

  • Suitable for permanent urinary catheters: Yes

  • Pack size: 10 leg bags

  • NHS Drug Tariff: Listed

  • Classification: Urinary drainage appliance / medical device

Order code:

  • 5170 – Conveen® Contour Leg Bag – 600ml45cm adjustable inlet tube – clamp outlet – Pack of 10

Other Conveen® Contour options:

  • 5172 – 600ml – 5cm fixed inlet tube – sterile

  • 5173 – 600ml – 30cm fixed inlet tube – sterile

  • 5175 – 800ml – 45cm fixed inlet tube – sterile

Coloplast Conveen® Contour 5170 combines a 600ml capacity, adjustable 45cm inlet tube, multiple-chamber construction, discreet clamp outlet and soft non-woven backing in a leg drainage bag designed for flexible and discreet daytime urine collection.

Always follow the manufacturer's instructions for use and any individual continence or catheter-care advice provided by an appropriate healthcare professional.

Coloplast Conveen® Contour 5170 is a 600ml urinary leg drainage bag with a 45cm adjustable inlet tube, designed for discreet daytime urine collection.

It can be used with a suitable urinary sheath or permanent urinary catheter, providing a practical urine collection system for people requiring continuous drainage during the day.

Unlike the fixed-length sterile Conveen® Contour variants, reference 5170 is the non-sterile adjustable-tube version. Its inlet tubing can be adjusted to provide a more individualised distance between the catheter or sheath connection and the drainage bag.

The Conveen® Contour design incorporates multiple internal chambers, which help distribute urine throughout the bag instead of allowing it to collect in a single compartment. This helps reduce movement and sloshing of urine and allows the bag to remain flatter and more discreet against the leg.

A compact clamp-style drainage outlet allows repeated emptying, while the soft non-woven backing provides a comfortable surface against the skin and helps reduce noise during movement.

Key features:

  • 600ml urinary leg drainage bag

  • Coloplast reference 5170

  • 45cm adjustable inlet tube

  • Tube can be adjusted to suit individual positioning requirements

  • Non-sterile version

  • Designed for daytime urinary drainage

  • Suitable for use with a compatible urinary sheath

  • Suitable for use with a permanent urinary catheter

  • Multiple internal chambers

  • Helps distribute urine throughout the bag

  • Helps reduce movement and sloshing of urine

  • Helps maintain a flatter profile against the leg

  • Designed for discreet wear beneath clothing

  • Compact clamp-style drainage outlet

  • Outlet design makes it easy to see whether the clamp is open or closed

  • Soft non-woven backing

  • Helps improve comfort against the leg

  • Helps reduce noise during movement

  • Drainable for repeated emptying during use

  • Pack of 10

Suitable for:

  • Daytime urinary drainage

  • Users of compatible male urinary sheaths

  • Permanent urinary catheter users

  • Ambulatory catheter users

  • Users requiring a 600ml capacity

  • Users requiring an adjustable inlet tube

  • Users who need greater flexibility in leg-bag positioning

  • Users who prefer a discreet multi-chamber drainage bag

  • Users who do not specifically require a sterile leg-bag version

600ml capacity

Conveen® Contour 5170 provides a 600ml urine collection capacity.

This offers a practical compromise between sufficient daytime urine capacity and a relatively discreet profile underneath clothing.

The bag should be emptied regularly and before it becomes excessively full or heavy.

Allowing a leg bag to become too full can:

  • Increase pulling on the catheter or urinary sheath

  • Make the bag more noticeable

  • Increase pressure on the leg

  • Place additional strain on the fixation system

  • Reduce comfort during walking and normal movement

45cm adjustable inlet tube

Reference 5170 has a 45cm inlet tube that can be adjusted to suit the required leg-bag position.

This distinguishes it from the fixed-tube Conveen® Contour options.

An adjustable tube allows the drainage system to be adapted according to:

  • Where the leg bag is positioned

  • The location of the catheter or sheath connection

  • The user's height and anatomy

  • Clothing

  • Mobility

  • Personal preference

The tube should be adjusted according to the manufacturer's instructions.

Once positioned, the drainage pathway should remain free from:

  • Kinks

  • Twisting

  • Compression

  • Excessive loops

  • Pulling on the catheter or urinary sheath

  • Obstruction beneath clothing

When used with a urinary catheter, the bag should remain below bladder level to allow effective gravity drainage.

Adjustable tube or fixed tube?

The Conveen® Contour range includes both adjustable and fixed inlet-tube versions.

5170 – Adjustable tube

The 45cm tube can be adjusted to provide a more individualised position of the drainage bag on the leg.

This may be useful where a standard fixed tube length does not provide the preferred positioning.

5172 – Fixed 5cm tube

A very short fixed inlet tube for users requiring the bag close to the catheter or sheath connection.

5173 – Fixed 30cm tube

A medium-length fixed tube for conventional leg positioning.

5175 – Fixed 45cm tube

A longer fixed tube combined with a larger 800ml capacity.

Multiple-chamber design

Conveen® Contour incorporates multiple internal chambers or channels.

Instead of collected urine accumulating in one large compartment, the chambers help distribute it across the drainage bag.

This can help:

  • Distribute urine more evenly

  • Reduce excessive bulging in one area

  • Keep the drainage bag flatter against the leg

  • Reduce movement of urine

  • Reduce noticeable sloshing

  • Improve discretion beneath clothing

  • Improve comfort during walking and movement

The multi-chamber construction is one of the principal features of the Conveen® Contour range.

Clamp drainage outlet

Conveen® Contour incorporates a compact clamp-style outlet for emptying the urine bag.

The clamp provides a straightforward opening and closing mechanism and allows the user to visually check whether the drainage outlet is correctly closed.

The small outlet design also helps minimise bulk at the bottom of the bag.

After emptying, always ensure the clamp is completely closed before repositioning the bag.

Soft non-woven backing

The skin-facing side of the Conveen® Contour bag incorporates a soft non-woven backing material.

This provides a more comfortable surface between the drainage bag and the leg and helps:

  • Improve comfort during prolonged wear

  • Allow the skin to breathe

  • Reduce noise during movement

  • Improve discretion underneath clothing

The skin underneath and around the bag should still be checked regularly for redness, moisture, pressure or irritation.

Using with a urinary catheter

Conveen® Contour 5170 can be used with an appropriate permanent urinary catheter.

When connecting the leg bag:

  • Wash and dry your hands

  • Ensure the drainage clamp is completely closed

  • Adjust the tube according to the manufacturer's instructions if required

  • Avoid touching the connection surfaces unnecessarily

  • Connect the leg bag securely to the catheter

  • Position the bag below bladder level

  • Ensure the tubing follows a natural route

  • Check that there are no kinks or obstructions

  • Confirm that urine is draining freely

Avoid disconnecting an established catheter drainage system unnecessarily.

Using with a urinary sheath

Conveen® Contour can also be connected to an appropriate male urinary sheath, including compatible Conveen® sheath systems.

The sheath directs urine through the connecting tubing and into the leg bag.

Correct sheath sizing and application are important to reduce the risk of:

  • Leakage

  • Skin irritation

  • Sheath detachment

  • Restriction

  • Poor drainage

Always follow the manufacturer's instructions supplied with the urinary sheath.

Positioning the leg bag

Secure the bag appropriately against the leg using a suitable leg-bag fixation system.

The adjustable inlet tube allows greater flexibility in positioning than a fixed-length tube.

Ensure that:

  • The tube has been adjusted correctly

  • The bag is comfortable during walking and sitting

  • The tubing is not kinked or compressed

  • There is no excessive tension on the catheter or sheath

  • The bag remains adequately supported as it fills

  • The drainage outlet remains easy to access

  • The bag remains below bladder level when used with a catheter

Avoid securing the bag so tightly that circulation is restricted.

Directions:

Wash and dry your hands thoroughly.

Remove the Conveen® Contour bag from its packaging.

Ensure the clamp drainage outlet is securely closed.

Adjust the inlet tube to the required length according to the manufacturer's instructions.

Position and secure the bag appropriately against the leg.

Connect the inlet securely to the urinary catheter or compatible urinary sheath.

Arrange the tubing so that it is free from kinks, compression and unnecessary tension.

When used with a urinary catheter, ensure the drainage bag remains below bladder level.

Check that urine is able to drain freely into the bag.

Emptying the bag:

Empty the leg bag regularly and before it becomes excessively full.

Wash your hands.

Position the outlet over a toilet or suitable receptacle.

Open the clamp outlet.

Allow the urine to drain completely.

Avoid allowing the drainage outlet to touch the toilet or receptacle.

Close the clamp securely.

Check visually that the outlet is fully closed.

Reposition the bag as required.

Wash your hands after handling the drainage system.

Changing the leg bag:

Replace the bag according to the manufacturer's instructions and the individual's catheter or continence-care plan.

Change the drainage bag sooner if:

  • The bag becomes damaged

  • Leakage develops

  • The clamp no longer closes securely

  • Tubing becomes damaged or obstructed

  • The connection becomes insecure

  • The drainage system becomes contaminated

  • A healthcare professional advises replacement

Avoid unnecessary disconnection of an established catheter drainage system.

Important information:

  • For urinary drainage

  • Reference 5170

  • 600ml capacity

  • 45cm adjustable inlet tube

  • Non-sterile

  • Do not confuse with sterile fixed-tube references 5172, 5173 or 5175

  • Multiple-chamber design

  • Clamp-style drainage outlet

  • Soft non-woven backing

  • Suitable for use with compatible urinary sheaths

  • Suitable for use with permanent urinary catheters

  • Adjust the inlet tube only according to the manufacturer's instructions

  • Keep the drainage bag below bladder level when connected to a catheter

  • Ensure tubing remains free from kinks and obstruction

  • Empty the bag regularly

  • Do not allow the bag to become excessively full or heavy

  • Avoid pulling or excessive tension on the catheter or urinary sheath

  • Secure the bag appropriately against the leg

  • Maintain appropriate hand hygiene

  • Avoid unnecessary disconnection of a catheter drainage system

  • Ensure the clamp is completely closed after emptying

  • Check regularly that urine is draining freely

  • Check the skin for redness, pressure or irritation

  • Seek clinical advice if urine unexpectedly stops draining

  • Seek appropriate healthcare advice for persistent leakage, catheter-associated pain, significant blood in the urine, fever, lower abdominal or flank pain, or other symptoms suggesting urinary infection or catheter complications

  • Always follow the manufacturer's instructions for use

Product details:

  • Product: Conveen® Contour Leg Bag

  • Manufacturer: Coloplast Ltd

  • Reference / order code: 5170

  • Product type: Urinary leg drainage bag

  • Capacity: 600ml

  • Inlet tube: 45cm adjustable tube

  • Tube type: Adjustable

  • Outlet: Clamp

  • Multiple chambers: Yes

  • Soft non-woven backing: Yes

  • Sterile: No

  • Drainable: Yes

  • Suitable for urinary sheaths: Yes

  • Suitable for permanent urinary catheters: Yes

  • Pack size: 10 leg bags

  • NHS Drug Tariff: Listed

  • Classification: Urinary drainage appliance / medical device

Order code:

  • 5170 – Conveen® Contour Leg Bag – 600ml45cm adjustable inlet tube – clamp outlet – Pack of 10

Other Conveen® Contour options:

  • 5172 – 600ml – 5cm fixed inlet tube – sterile

  • 5173 – 600ml – 30cm fixed inlet tube – sterile

  • 5175 – 800ml – 45cm fixed inlet tube – sterile

Coloplast Conveen® Contour 5170 combines a 600ml capacity, adjustable 45cm inlet tube, multiple-chamber construction, discreet clamp outlet and soft non-woven backing in a leg drainage bag designed for flexible and discreet daytime urine collection.

Always follow the manufacturer's instructions for use and any individual continence or catheter-care advice provided by an appropriate healthcare professional.