LINC-Flo® Sterile Urine Drainage Leg Bag – 750ml, Adjustable Tube, Lever Tap – Pack of 10 (Ref: LM750AD-L)
Pictures are for illustration purposes only
LINC-Flo® LM750AD-L is a sterile 750ml urine drainage leg bag with an adjustable inlet tube and lever tap, designed for comfortable and discreet daytime urine collection from an indwelling urinary catheter or other appropriate urinary drainage system.
The adjustable inlet tubing allows the drainage setup to be adapted to the individual user's required bag position, while the larger 750ml capacity provides additional collection volume compared with standard 350ml or 500ml leg bags.
The bag incorporates a soft fabric backing, discreet triple-chamber construction, needle-free sample port, lever-operated drainage tap and overnight drainage connector. Adjustable LINC-Flo® bags are also supplied with scissors to assist with preparation of the adjustable tubing.
Key features:
-
Sterile urine drainage leg bag
-
LINC-Flo® range
-
Reference LM750AD-L
-
750ml capacity
-
Adjustable inlet tube
-
Lever tap
-
Easy one-handed tap operation
-
Needle-free urine sampling port
-
Soft fabric backing
-
Discreet triple-chamber design
-
Designed to conform comfortably to the leg
-
Helps reduce movement and sloshing of urine within the bag
-
Overnight drainage connector
-
Suitable for appropriate link drainage with a night bag
-
Elastic leg straps supplied
-
Latex-free gloves supplied
-
Adjustable version supplied with scissors
-
Pack of 10
Suitable for:
-
People using an indwelling urinary catheter
-
Urethral catheters
-
Suprapubic catheters
-
Appropriate urinary drainage systems
-
Users requiring a larger 750ml daytime capacity
-
Users requiring adjustable inlet tubing
-
Users who prefer a lever-operated tap
-
Users requiring flexible positioning of the leg bag
-
Users requiring a needle-free urine sampling port
-
Users who may connect their leg bag to an appropriate overnight drainage system
750ml capacity
The 750ml capacity provides greater urine collection volume than smaller 350ml and 500ml leg bags.
This may be particularly useful where:
-
Urine output is relatively high
-
More capacity is required between emptying
-
Access to a toilet may be less frequent
-
A larger daytime drainage capacity is preferred
-
Frequent emptying of a smaller bag is inconvenient
The bag should still be emptied regularly and before becoming excessively full or heavy.
Allowing a leg bag to become overly full may:
-
Increase pulling on the catheter
-
Increase tension on the tubing
-
Make the bag more noticeable beneath clothing
-
Increase pressure from the leg straps
-
Reduce comfort during movement
Adjustable inlet tube
Reference LM750AD-L has an adjustable inlet tube.
Unlike fixed direct, short or long-tube leg bags, the adjustable version allows the tubing arrangement to be tailored more closely to the individual user's required bag position.
This provides additional flexibility where:
-
A standard fixed tube length is unsuitable
-
The bag needs to be positioned at a particular point on the leg
-
The user's height requires additional positioning flexibility
-
Catheter position varies
-
Clothing affects where the bag can comfortably be worn
LINC supplies scissors with the adjustable version for preparation of the tubing.
Always prepare and position the tubing according to the manufacturer's instructions.
The tubing should allow unrestricted urine drainage without:
-
Kinks
-
Tight bends
-
Compression
-
Excessive loops
-
Pulling on the catheter
Lever tap
LM750AD-L incorporates a lever-operated drainage tap.
The lever tap is designed for straightforward operation and can be operated one-handed.
To empty the bag:
-
Perform appropriate hand hygiene
-
Position the outlet over a toilet or suitable receptacle
-
Operate the lever according to the manufacturer's instructions
-
Allow urine to drain
-
Avoid allowing the outlet to touch the toilet or receptacle
-
Return the lever securely to the closed position
-
Check that drainage has stopped before repositioning clothing
Always ensure the tap is fully closed following emptying.
Lever Tap versus T-Tap
The final letter of the LINC-Flo® product reference identifies the outlet type.
For this product:
LM750AD-L
the “-L” indicates Lever Tap.
The corresponding 750ml adjustable-tube version with a T-Tap is:
LM750AD-T
It is therefore important to check the complete product code when ordering.
Soft fabric backing
LINC-Flo® leg bags incorporate a soft fabric backing designed to sit comfortably against the leg.
The backing helps:
-
Reduce direct contact between plastic film and the skin
-
Improve comfort
-
Provide a softer surface against the leg
-
Support discreet everyday wear
The bag should still be positioned and supported correctly to avoid unnecessary pressure or friction.
Triple-chamber design
LINC-Flo® incorporates a discreet triple-chamber design.
The chambers help distribute urine throughout the bag rather than allowing the contents to move freely within one large compartment.
This design helps the bag:
-
Conform more closely to the leg
-
Maintain a lower-profile appearance
-
Reduce excessive movement of urine
-
Reduce sloshing noise
-
Improve stability as the bag fills
This can improve both comfort and discretion during normal activity.
Needle-free sample port
The bag includes a needle-free urine sampling port.
This provides an appropriate access point for an appropriately trained healthcare professional to obtain a urine sample without puncturing the drainage tubing with a needle.
The sampling port helps preserve the integrity of the drainage system when correct sampling technique is used.
Urine samples should be obtained using appropriate clinical and infection-control procedures.
Daytime urinary drainage
LINC-Flo® leg bags are designed primarily for daytime urinary drainage.
The collection bag can be secured to the leg using the supplied straps, allowing the user to remain mobile while urine drains continuously from the catheter.
Correct positioning helps:
-
Maintain free urine flow
-
Reduce pulling on the catheter
-
Reduce excessive bag movement
-
Improve comfort
-
Maintain discretion beneath clothing
The drainage bag should normally remain below the level of the bladder to support gravity drainage.
Leg straps supplied
LINC-Flo® sterile leg bags are supplied with elastic leg straps.
The NHS Drug Tariff specifies 10 pairs of straps per box of 10 leg bags.
The straps should:
-
Secure the bag comfortably
-
Prevent excessive movement
-
Allow normal circulation
-
Avoid excessive pressure
-
Support the increasing weight of the bag as it fills
Do not overtighten the straps.
Check the skin beneath the straps regularly for:
-
Redness
-
Pressure marks
-
Irritation
-
Discomfort
Latex-free gloves supplied
Each LINC-Flo® leg bag is supplied with latex-free gloves to support hygienic handling during bag changes.
Appropriate hand hygiene should always be performed before and after handling the catheter drainage system.
Avoid touching catheter and bag connection surfaces unnecessarily.
Overnight drainage connector
LINC-Flo® sterile leg bags incorporate an overnight drainage connector.
This allows the leg bag to form part of an appropriate link-drainage system with a larger night drainage bag when additional overnight capacity is required.
In a link-drainage arrangement, the leg bag remains connected to the catheter and the night bag is connected to the leg bag.
When using overnight drainage:
-
Use an appropriate compatible night drainage bag
-
Keep the leg bag connected to the catheter
-
Connect the night drainage system according to the manufacturer's instructions
-
Position the night bag below bladder level
-
Keep tubing free from kinks
-
Avoid trapping tubing beneath the body or bedding
-
Prevent the tubing from pulling on the catheter
-
Check that urine can drain freely
Maintaining a closed drainage system and avoiding unnecessary catheter disconnection is important in catheter management.
Positioning the leg bag
The adjustable inlet tube allows the bag position to be tailored according to the user's individual requirements.
Position depends on factors including:
-
Catheter type
-
Catheter location
-
User height
-
Leg shape
-
Mobility
-
Clothing
-
Preferred bag position
After positioning, check that:
-
The bag remains below bladder level
-
The catheter is not under tension
-
The tubing is not kinked
-
Clothing is not compressing the tubing
-
The bag is adequately supported
-
Urine can drain freely
Emptying the bag
Empty the bag regularly and before it becomes excessively full.
To empty:
-
Perform appropriate hand hygiene
-
Position the lever-tap outlet over a toilet or suitable receptacle
-
Open the lever tap
-
Allow urine to drain completely
-
Avoid contaminating the outlet
-
Close the lever securely
-
Check that the tap is completely closed
-
Perform hand hygiene afterwards
Regular emptying reduces excessive weight pulling on the catheter and leg-bag supports.
Changing the leg bag
The leg bag should be replaced according to the manufacturer's instructions and the user's individual catheter-care plan.
Replace the bag sooner if:
-
Leakage develops
-
The bag becomes damaged
-
Tubing becomes damaged
-
The lever tap no longer closes correctly
-
Drainage becomes impaired
-
The connector becomes contaminated
-
The bag has been disconnected and should not be reused
-
A healthcare professional advises replacement
Do not continue using a damaged or leaking urinary drainage bag.
Important information:
-
Sterile urinary drainage leg bag
-
Reference LM750AD-L
-
750ml capacity
-
Adjustable inlet tubing
-
Lever tap
-
Easy one-handed tap operation
-
Needle-free sampling port
-
Soft fabric backing
-
Triple-chamber design
-
Overnight drainage connector
-
Elastic leg straps supplied
-
Latex-free gloves supplied
-
Scissors supplied with adjustable version
-
Pack of 10
-
Keep the bag below bladder level
-
Keep tubing free from kinks and compression
-
Ensure the catheter is not under tension
-
Support the bag securely as it fills
-
Empty before it becomes excessively full
-
Ensure the lever tap is fully closed after emptying
-
Maintain appropriate hand hygiene
-
Avoid unnecessary disconnection of the urinary drainage system
-
Check the skin beneath straps regularly
-
Replace the bag if damaged, leaking or no longer draining correctly
-
Seek appropriate clinical advice if urine unexpectedly stops draining or catheter blockage is suspected
-
Fever, flank pain, significant lower abdominal pain, visible blood in the urine or other symptoms suggesting urinary infection or catheter complications require appropriate clinical assessment
-
Always follow the manufacturer's instructions and individual catheter-care plan
Product details:
-
Product: LINC-Flo® Sterile Urine Drainage Leg Bag
-
Manufacturer: LINC Medical Systems Ltd
-
Reference / order code: LM750AD-L
-
Capacity: 750ml
-
Inlet tube: Adjustable
-
Tap: Lever Tap
-
Tap operation: One-handed
-
Sample port: Needle-free
-
Backing: Soft fabric
-
Bag construction: Triple chamber
-
Sterile: Yes
-
Overnight connector: Yes
-
Link drainage compatible: Yes, with an appropriate night drainage system
-
Leg straps: Supplied
-
Latex-free gloves: Supplied
-
Scissors: Supplied with adjustable version
-
Pack size: 10 leg bags
-
NHS Drug Tariff: Listed
-
Classification: Urinary drainage appliance / medical device
Order code:
-
LM750AD-L – LINC-Flo® Sterile Urine Drainage Leg Bag – 750ml – Adjustable Inlet Tube – Lever Tap – Pack of 10
Related LINC-Flo® 750ml options:
-
LM750AD-T – 750ml – Adjustable Inlet Tube – T-Tap
-
LM750MD-T – 750ml – 10cm Inlet Tube – T-Tap
-
LM750LD-T – 750ml – 30cm Inlet Tube – T-Tap
-
LM750SD-T – 750ml – Direct Inlet – T-Tap
LINC-Flo® LM750AD-L combines a 750ml sterile urine drainage bag, adjustable inlet tubing, one-handed lever tap, needle-free sampling port, soft fabric backing and discreet triple-chamber construction for flexible daytime catheter drainage.
The adjustable tubing makes this version particularly useful where a fixed tube length does not provide the required positioning, while the larger 750ml capacity provides additional collection volume for users who prefer fewer emptying episodes.
Always follow the manufacturer's instructions and the user's individual catheter-care plan.
Pictures are for illustration purposes only
LINC-Flo® LM750AD-L is a sterile 750ml urine drainage leg bag with an adjustable inlet tube and lever tap, designed for comfortable and discreet daytime urine collection from an indwelling urinary catheter or other appropriate urinary drainage system.
The adjustable inlet tubing allows the drainage setup to be adapted to the individual user's required bag position, while the larger 750ml capacity provides additional collection volume compared with standard 350ml or 500ml leg bags.
The bag incorporates a soft fabric backing, discreet triple-chamber construction, needle-free sample port, lever-operated drainage tap and overnight drainage connector. Adjustable LINC-Flo® bags are also supplied with scissors to assist with preparation of the adjustable tubing.
Key features:
-
Sterile urine drainage leg bag
-
LINC-Flo® range
-
Reference LM750AD-L
-
750ml capacity
-
Adjustable inlet tube
-
Lever tap
-
Easy one-handed tap operation
-
Needle-free urine sampling port
-
Soft fabric backing
-
Discreet triple-chamber design
-
Designed to conform comfortably to the leg
-
Helps reduce movement and sloshing of urine within the bag
-
Overnight drainage connector
-
Suitable for appropriate link drainage with a night bag
-
Elastic leg straps supplied
-
Latex-free gloves supplied
-
Adjustable version supplied with scissors
-
Pack of 10
Suitable for:
-
People using an indwelling urinary catheter
-
Urethral catheters
-
Suprapubic catheters
-
Appropriate urinary drainage systems
-
Users requiring a larger 750ml daytime capacity
-
Users requiring adjustable inlet tubing
-
Users who prefer a lever-operated tap
-
Users requiring flexible positioning of the leg bag
-
Users requiring a needle-free urine sampling port
-
Users who may connect their leg bag to an appropriate overnight drainage system
750ml capacity
The 750ml capacity provides greater urine collection volume than smaller 350ml and 500ml leg bags.
This may be particularly useful where:
-
Urine output is relatively high
-
More capacity is required between emptying
-
Access to a toilet may be less frequent
-
A larger daytime drainage capacity is preferred
-
Frequent emptying of a smaller bag is inconvenient
The bag should still be emptied regularly and before becoming excessively full or heavy.
Allowing a leg bag to become overly full may:
-
Increase pulling on the catheter
-
Increase tension on the tubing
-
Make the bag more noticeable beneath clothing
-
Increase pressure from the leg straps
-
Reduce comfort during movement
Adjustable inlet tube
Reference LM750AD-L has an adjustable inlet tube.
Unlike fixed direct, short or long-tube leg bags, the adjustable version allows the tubing arrangement to be tailored more closely to the individual user's required bag position.
This provides additional flexibility where:
-
A standard fixed tube length is unsuitable
-
The bag needs to be positioned at a particular point on the leg
-
The user's height requires additional positioning flexibility
-
Catheter position varies
-
Clothing affects where the bag can comfortably be worn
LINC supplies scissors with the adjustable version for preparation of the tubing.
Always prepare and position the tubing according to the manufacturer's instructions.
The tubing should allow unrestricted urine drainage without:
-
Kinks
-
Tight bends
-
Compression
-
Excessive loops
-
Pulling on the catheter
Lever tap
LM750AD-L incorporates a lever-operated drainage tap.
The lever tap is designed for straightforward operation and can be operated one-handed.
To empty the bag:
-
Perform appropriate hand hygiene
-
Position the outlet over a toilet or suitable receptacle
-
Operate the lever according to the manufacturer's instructions
-
Allow urine to drain
-
Avoid allowing the outlet to touch the toilet or receptacle
-
Return the lever securely to the closed position
-
Check that drainage has stopped before repositioning clothing
Always ensure the tap is fully closed following emptying.
Lever Tap versus T-Tap
The final letter of the LINC-Flo® product reference identifies the outlet type.
For this product:
LM750AD-L
the “-L” indicates Lever Tap.
The corresponding 750ml adjustable-tube version with a T-Tap is:
LM750AD-T
It is therefore important to check the complete product code when ordering.
Soft fabric backing
LINC-Flo® leg bags incorporate a soft fabric backing designed to sit comfortably against the leg.
The backing helps:
-
Reduce direct contact between plastic film and the skin
-
Improve comfort
-
Provide a softer surface against the leg
-
Support discreet everyday wear
The bag should still be positioned and supported correctly to avoid unnecessary pressure or friction.
Triple-chamber design
LINC-Flo® incorporates a discreet triple-chamber design.
The chambers help distribute urine throughout the bag rather than allowing the contents to move freely within one large compartment.
This design helps the bag:
-
Conform more closely to the leg
-
Maintain a lower-profile appearance
-
Reduce excessive movement of urine
-
Reduce sloshing noise
-
Improve stability as the bag fills
This can improve both comfort and discretion during normal activity.
Needle-free sample port
The bag includes a needle-free urine sampling port.
This provides an appropriate access point for an appropriately trained healthcare professional to obtain a urine sample without puncturing the drainage tubing with a needle.
The sampling port helps preserve the integrity of the drainage system when correct sampling technique is used.
Urine samples should be obtained using appropriate clinical and infection-control procedures.
Daytime urinary drainage
LINC-Flo® leg bags are designed primarily for daytime urinary drainage.
The collection bag can be secured to the leg using the supplied straps, allowing the user to remain mobile while urine drains continuously from the catheter.
Correct positioning helps:
-
Maintain free urine flow
-
Reduce pulling on the catheter
-
Reduce excessive bag movement
-
Improve comfort
-
Maintain discretion beneath clothing
The drainage bag should normally remain below the level of the bladder to support gravity drainage.
Leg straps supplied
LINC-Flo® sterile leg bags are supplied with elastic leg straps.
The NHS Drug Tariff specifies 10 pairs of straps per box of 10 leg bags.
The straps should:
-
Secure the bag comfortably
-
Prevent excessive movement
-
Allow normal circulation
-
Avoid excessive pressure
-
Support the increasing weight of the bag as it fills
Do not overtighten the straps.
Check the skin beneath the straps regularly for:
-
Redness
-
Pressure marks
-
Irritation
-
Discomfort
Latex-free gloves supplied
Each LINC-Flo® leg bag is supplied with latex-free gloves to support hygienic handling during bag changes.
Appropriate hand hygiene should always be performed before and after handling the catheter drainage system.
Avoid touching catheter and bag connection surfaces unnecessarily.
Overnight drainage connector
LINC-Flo® sterile leg bags incorporate an overnight drainage connector.
This allows the leg bag to form part of an appropriate link-drainage system with a larger night drainage bag when additional overnight capacity is required.
In a link-drainage arrangement, the leg bag remains connected to the catheter and the night bag is connected to the leg bag.
When using overnight drainage:
-
Use an appropriate compatible night drainage bag
-
Keep the leg bag connected to the catheter
-
Connect the night drainage system according to the manufacturer's instructions
-
Position the night bag below bladder level
-
Keep tubing free from kinks
-
Avoid trapping tubing beneath the body or bedding
-
Prevent the tubing from pulling on the catheter
-
Check that urine can drain freely
Maintaining a closed drainage system and avoiding unnecessary catheter disconnection is important in catheter management.
Positioning the leg bag
The adjustable inlet tube allows the bag position to be tailored according to the user's individual requirements.
Position depends on factors including:
-
Catheter type
-
Catheter location
-
User height
-
Leg shape
-
Mobility
-
Clothing
-
Preferred bag position
After positioning, check that:
-
The bag remains below bladder level
-
The catheter is not under tension
-
The tubing is not kinked
-
Clothing is not compressing the tubing
-
The bag is adequately supported
-
Urine can drain freely
Emptying the bag
Empty the bag regularly and before it becomes excessively full.
To empty:
-
Perform appropriate hand hygiene
-
Position the lever-tap outlet over a toilet or suitable receptacle
-
Open the lever tap
-
Allow urine to drain completely
-
Avoid contaminating the outlet
-
Close the lever securely
-
Check that the tap is completely closed
-
Perform hand hygiene afterwards
Regular emptying reduces excessive weight pulling on the catheter and leg-bag supports.
Changing the leg bag
The leg bag should be replaced according to the manufacturer's instructions and the user's individual catheter-care plan.
Replace the bag sooner if:
-
Leakage develops
-
The bag becomes damaged
-
Tubing becomes damaged
-
The lever tap no longer closes correctly
-
Drainage becomes impaired
-
The connector becomes contaminated
-
The bag has been disconnected and should not be reused
-
A healthcare professional advises replacement
Do not continue using a damaged or leaking urinary drainage bag.
Important information:
-
Sterile urinary drainage leg bag
-
Reference LM750AD-L
-
750ml capacity
-
Adjustable inlet tubing
-
Lever tap
-
Easy one-handed tap operation
-
Needle-free sampling port
-
Soft fabric backing
-
Triple-chamber design
-
Overnight drainage connector
-
Elastic leg straps supplied
-
Latex-free gloves supplied
-
Scissors supplied with adjustable version
-
Pack of 10
-
Keep the bag below bladder level
-
Keep tubing free from kinks and compression
-
Ensure the catheter is not under tension
-
Support the bag securely as it fills
-
Empty before it becomes excessively full
-
Ensure the lever tap is fully closed after emptying
-
Maintain appropriate hand hygiene
-
Avoid unnecessary disconnection of the urinary drainage system
-
Check the skin beneath straps regularly
-
Replace the bag if damaged, leaking or no longer draining correctly
-
Seek appropriate clinical advice if urine unexpectedly stops draining or catheter blockage is suspected
-
Fever, flank pain, significant lower abdominal pain, visible blood in the urine or other symptoms suggesting urinary infection or catheter complications require appropriate clinical assessment
-
Always follow the manufacturer's instructions and individual catheter-care plan
Product details:
-
Product: LINC-Flo® Sterile Urine Drainage Leg Bag
-
Manufacturer: LINC Medical Systems Ltd
-
Reference / order code: LM750AD-L
-
Capacity: 750ml
-
Inlet tube: Adjustable
-
Tap: Lever Tap
-
Tap operation: One-handed
-
Sample port: Needle-free
-
Backing: Soft fabric
-
Bag construction: Triple chamber
-
Sterile: Yes
-
Overnight connector: Yes
-
Link drainage compatible: Yes, with an appropriate night drainage system
-
Leg straps: Supplied
-
Latex-free gloves: Supplied
-
Scissors: Supplied with adjustable version
-
Pack size: 10 leg bags
-
NHS Drug Tariff: Listed
-
Classification: Urinary drainage appliance / medical device
Order code:
-
LM750AD-L – LINC-Flo® Sterile Urine Drainage Leg Bag – 750ml – Adjustable Inlet Tube – Lever Tap – Pack of 10
Related LINC-Flo® 750ml options:
-
LM750AD-T – 750ml – Adjustable Inlet Tube – T-Tap
-
LM750MD-T – 750ml – 10cm Inlet Tube – T-Tap
-
LM750LD-T – 750ml – 30cm Inlet Tube – T-Tap
-
LM750SD-T – 750ml – Direct Inlet – T-Tap
LINC-Flo® LM750AD-L combines a 750ml sterile urine drainage bag, adjustable inlet tubing, one-handed lever tap, needle-free sampling port, soft fabric backing and discreet triple-chamber construction for flexible daytime catheter drainage.
The adjustable tubing makes this version particularly useful where a fixed tube length does not provide the required positioning, while the larger 750ml capacity provides additional collection volume for users who prefer fewer emptying episodes.
Always follow the manufacturer's instructions and the user's individual catheter-care plan.