Bard Spirit® Sterile Urine Drainage Leg Bag – 350ml, 30cm Long Tube – Pack of 10 (Ref: DSLB350L)

£43.65
In stock

Bard Spirit® DSLB350L is a sterile 350ml urine drainage leg bag with a 30cm long inlet tube, designed for discreet daytime collection of urine from an indwelling urinary catheter or compatible external urinary drainage system.

The compact 350ml capacity provides a lower-profile option for users who prefer a smaller leg bag, while the 30cm long tube provides additional flexibility for positioning the bag further down the leg.

The Spirit® leg bag incorporates a 180° FLIP-FLO® lever tap, universal ridged connector and a needle-free urine sampling port, providing a practical drainage system for everyday catheter management.

Key features:

  • Sterile urine drainage leg bag

  • Bard Spirit® range

  • Reference DSLB350L

  • 350ml capacity

  • 30cm long inlet tube

  • Designed for daytime urinary drainage

  • 180° FLIP-FLO® lever tap

  • Low-profile drainage tap

  • Universal ridged connector

  • Needle-free sampling port

  • Suitable for appropriate urinary catheter systems

  • Suitable for compatible external urinary sheath systems

  • Can be used with an appropriate overnight link-drainage system

  • Compact design for greater discretion

  • Leg straps supplied

  • Sterile latex-free gloves supplied

  • Pack of 10

Suitable for:

  • Indwelling urinary catheters

  • Urethral catheters

  • Suprapubic catheters

  • Appropriate external urinary sheath systems

  • Users requiring a 350ml daytime leg bag

  • Users requiring a 30cm long tube

  • Users positioning the drainage bag further down the leg

  • Users who prefer a smaller-capacity, discreet leg bag

  • Users requiring a lever-operated drainage tap

350ml capacity

The 350ml capacity provides a compact alternative to larger 500ml or 750ml leg bags.

It may be particularly suitable where:

  • A smaller pouch is more discreet beneath clothing

  • Lower weight on the leg is preferred

  • The user is able to empty the bag regularly

  • Reduced bulk is important during everyday activity

Because the capacity is smaller, it may require more frequent emptying depending on individual urine output.

The bag should be emptied before it becomes excessively full or heavy.

Regular emptying helps:

  • Reduce pulling on the catheter

  • Reduce tension on the tubing

  • Improve comfort

  • Reduce movement of the bag on the leg

  • Maintain discretion beneath clothing

30cm long tube

Reference DSLB350L incorporates a 30cm long inlet tube.

The additional tubing length provides greater flexibility when positioning the bag further down the leg.

It may be particularly useful where:

  • The bag is worn around the calf

  • Additional distance is required between the catheter and drainage bag

  • Clothing makes lower-leg positioning preferable

  • A short-tube bag does not provide sufficient positioning flexibility

The tubing should be positioned to allow urine to drain freely.

Avoid:

  • Kinks

  • Twisting

  • Compression

  • Excessive loops

  • Pulling on the catheter

The drainage bag should remain below bladder level to support gravity drainage.

180° FLIP-FLO® lever tap

The Spirit® leg bag incorporates a 180° FLIP-FLO® lever tap for controlled emptying.

The lever tap provides straightforward operation and has a relatively flat profile against the leg.

To empty the bag:

  • Position the outlet over a toilet or suitable receptacle

  • Operate the lever according to the manufacturer's instructions

  • Allow the urine to drain completely

  • Avoid allowing the outlet to touch the toilet or receptacle

  • Return the lever to the closed position

  • Check that the tap is completely closed before repositioning clothing

Universal ridged connector

The bag incorporates a universal ridged connector designed to provide a secure connection to an appropriate urinary drainage system.

When connecting the bag:

  • Wash and dry your hands

  • Avoid touching connection surfaces unnecessarily

  • Push the connector securely into position

  • Check that the connection is stable

  • Avoid unnecessary disconnection and reconnection

Maintaining a closed urinary drainage system wherever possible helps reduce unnecessary manipulation of the catheter system.

Needle-free sampling port

Spirit® leg bags incorporate a needle-free sampling port.

This allows an appropriately trained healthcare professional to obtain a urine sample without puncturing the drainage tubing with a needle.

Urine sampling should always be carried out using appropriate clinical and infection-control procedures.

Daytime urinary drainage

A leg bag allows urine to drain continuously while the user remains mobile.

The bag can be secured to the leg using the supplied straps or another appropriate support system.

Correct positioning helps:

  • Maintain unrestricted urine flow

  • Reduce pulling on the catheter

  • Improve comfort

  • Prevent excessive bag movement

  • Maintain discretion beneath clothing

The bag should be properly supported rather than allowing its weight to hang directly from the catheter.

Leg straps

Spirit® leg bags are supplied with leg straps to secure the drainage bag in position.

The straps should:

  • Hold the bag securely

  • Avoid restricting circulation

  • Avoid excessive pressure

  • Prevent unnecessary movement

  • Remain comfortable during normal activity

Check the skin beneath and around the straps regularly for redness, pressure marks or irritation.

Connection to overnight drainage

The Spirit® leg bag may be used as part of an appropriate link-drainage system with a compatible larger-capacity night drainage bag.

This allows urine to drain through the daytime leg bag into the night bag while sleeping.

When using overnight drainage:

  • Use a compatible drainage system

  • Ensure all connections are secure

  • Position the night bag below bladder level

  • Keep tubing free from kinks

  • Avoid trapping tubing beneath the body or bedding

  • Ensure the tubing does not pull on the catheter or leg bag

  • Check that urine can flow freely

Always follow the manufacturer's instructions supplied with both drainage systems.

Changing the leg bag

The bag should be changed according to the manufacturer's instructions and the user's individual catheter-care plan.

Replace the bag earlier if:

  • Leakage occurs

  • The bag becomes damaged

  • Tubing becomes damaged

  • Drainage becomes impaired

  • The connector becomes contaminated

  • The lever tap no longer closes securely

  • A healthcare professional recommends replacement

Do not continue using a damaged or leaking drainage bag.

Important information:

  • Sterile urinary drainage leg bag

  • Reference DSLB350L

  • 350ml capacity

  • 30cm long tube

  • 180° FLIP-FLO® lever tap

  • Universal ridged connector

  • Needle-free sampling port

  • Designed for daytime urine collection

  • Compact capacity for improved discretion

  • Suitable for appropriate catheter and external urinary drainage systems

  • Suitable for compatible overnight link drainage

  • Keep the bag below bladder level

  • Keep tubing free from kinks and compression

  • Ensure the bag is properly supported

  • Empty the bag before it becomes excessively full

  • Check that the lever tap is completely closed after emptying

  • Maintain appropriate hand hygiene when handling the drainage system

  • Avoid unnecessary disconnection of the drainage system

  • Check the skin beneath straps for pressure or irritation

  • Replace the bag if damaged, leaking or no longer draining correctly

  • Seek appropriate clinical advice if urine unexpectedly stops draining or catheter blockage is suspected

  • Fever, flank pain, significant lower abdominal pain, blood in the urine or other symptoms suggesting urinary infection or catheter complications require appropriate clinical assessment

  • Always follow the manufacturer's instructions and the individual catheter-care plan

Product details:

  • Product: Spirit® Sterile Urine Drainage Leg Bag

  • Manufacturer: Bard Ltd

  • Reference / order code: DSLB350L

  • Capacity: 350ml

  • Tube length: 30cm

  • Tube type: Long tube

  • Tap: 180° FLIP-FLO® lever tap

  • Connector: Universal ridged connector

  • Sampling port: Needle-free

  • Sterile: Yes

  • Application: Daytime urinary drainage

  • Leg mounted: Yes

  • Overnight link drainage compatible: Yes, with an appropriate compatible system

  • Leg straps: Supplied

  • Sterile gloves: Supplied

  • Pack size: 10 leg bags

  • NHS Drug Tariff: Listed

  • Classification: Urinary drainage appliance / medical device

Order code:

  • DSLB350L – Spirit® Sterile Urine Drainage Leg Bag – 350ml – 30cm Long Tube – Lever Tap – Pack of 10

Bard Spirit® DSLB350L combines a compact 350ml sterile drainage bag, 30cm long tube, 180° FLIP-FLO® lever tap, universal ridged connector and needle-free sampling port in a practical leg-mounted urine collection system.

The smaller 350ml capacity provides a discreet option for daytime use, while the 30cm tubing offers additional flexibility for positioning the bag lower on the leg.

Always follow the manufacturer's instructions and the user's individual catheter-care plan.

Bard Spirit® DSLB350L is a sterile 350ml urine drainage leg bag with a 30cm long inlet tube, designed for discreet daytime collection of urine from an indwelling urinary catheter or compatible external urinary drainage system.

The compact 350ml capacity provides a lower-profile option for users who prefer a smaller leg bag, while the 30cm long tube provides additional flexibility for positioning the bag further down the leg.

The Spirit® leg bag incorporates a 180° FLIP-FLO® lever tap, universal ridged connector and a needle-free urine sampling port, providing a practical drainage system for everyday catheter management.

Key features:

  • Sterile urine drainage leg bag

  • Bard Spirit® range

  • Reference DSLB350L

  • 350ml capacity

  • 30cm long inlet tube

  • Designed for daytime urinary drainage

  • 180° FLIP-FLO® lever tap

  • Low-profile drainage tap

  • Universal ridged connector

  • Needle-free sampling port

  • Suitable for appropriate urinary catheter systems

  • Suitable for compatible external urinary sheath systems

  • Can be used with an appropriate overnight link-drainage system

  • Compact design for greater discretion

  • Leg straps supplied

  • Sterile latex-free gloves supplied

  • Pack of 10

Suitable for:

  • Indwelling urinary catheters

  • Urethral catheters

  • Suprapubic catheters

  • Appropriate external urinary sheath systems

  • Users requiring a 350ml daytime leg bag

  • Users requiring a 30cm long tube

  • Users positioning the drainage bag further down the leg

  • Users who prefer a smaller-capacity, discreet leg bag

  • Users requiring a lever-operated drainage tap

350ml capacity

The 350ml capacity provides a compact alternative to larger 500ml or 750ml leg bags.

It may be particularly suitable where:

  • A smaller pouch is more discreet beneath clothing

  • Lower weight on the leg is preferred

  • The user is able to empty the bag regularly

  • Reduced bulk is important during everyday activity

Because the capacity is smaller, it may require more frequent emptying depending on individual urine output.

The bag should be emptied before it becomes excessively full or heavy.

Regular emptying helps:

  • Reduce pulling on the catheter

  • Reduce tension on the tubing

  • Improve comfort

  • Reduce movement of the bag on the leg

  • Maintain discretion beneath clothing

30cm long tube

Reference DSLB350L incorporates a 30cm long inlet tube.

The additional tubing length provides greater flexibility when positioning the bag further down the leg.

It may be particularly useful where:

  • The bag is worn around the calf

  • Additional distance is required between the catheter and drainage bag

  • Clothing makes lower-leg positioning preferable

  • A short-tube bag does not provide sufficient positioning flexibility

The tubing should be positioned to allow urine to drain freely.

Avoid:

  • Kinks

  • Twisting

  • Compression

  • Excessive loops

  • Pulling on the catheter

The drainage bag should remain below bladder level to support gravity drainage.

180° FLIP-FLO® lever tap

The Spirit® leg bag incorporates a 180° FLIP-FLO® lever tap for controlled emptying.

The lever tap provides straightforward operation and has a relatively flat profile against the leg.

To empty the bag:

  • Position the outlet over a toilet or suitable receptacle

  • Operate the lever according to the manufacturer's instructions

  • Allow the urine to drain completely

  • Avoid allowing the outlet to touch the toilet or receptacle

  • Return the lever to the closed position

  • Check that the tap is completely closed before repositioning clothing

Universal ridged connector

The bag incorporates a universal ridged connector designed to provide a secure connection to an appropriate urinary drainage system.

When connecting the bag:

  • Wash and dry your hands

  • Avoid touching connection surfaces unnecessarily

  • Push the connector securely into position

  • Check that the connection is stable

  • Avoid unnecessary disconnection and reconnection

Maintaining a closed urinary drainage system wherever possible helps reduce unnecessary manipulation of the catheter system.

Needle-free sampling port

Spirit® leg bags incorporate a needle-free sampling port.

This allows an appropriately trained healthcare professional to obtain a urine sample without puncturing the drainage tubing with a needle.

Urine sampling should always be carried out using appropriate clinical and infection-control procedures.

Daytime urinary drainage

A leg bag allows urine to drain continuously while the user remains mobile.

The bag can be secured to the leg using the supplied straps or another appropriate support system.

Correct positioning helps:

  • Maintain unrestricted urine flow

  • Reduce pulling on the catheter

  • Improve comfort

  • Prevent excessive bag movement

  • Maintain discretion beneath clothing

The bag should be properly supported rather than allowing its weight to hang directly from the catheter.

Leg straps

Spirit® leg bags are supplied with leg straps to secure the drainage bag in position.

The straps should:

  • Hold the bag securely

  • Avoid restricting circulation

  • Avoid excessive pressure

  • Prevent unnecessary movement

  • Remain comfortable during normal activity

Check the skin beneath and around the straps regularly for redness, pressure marks or irritation.

Connection to overnight drainage

The Spirit® leg bag may be used as part of an appropriate link-drainage system with a compatible larger-capacity night drainage bag.

This allows urine to drain through the daytime leg bag into the night bag while sleeping.

When using overnight drainage:

  • Use a compatible drainage system

  • Ensure all connections are secure

  • Position the night bag below bladder level

  • Keep tubing free from kinks

  • Avoid trapping tubing beneath the body or bedding

  • Ensure the tubing does not pull on the catheter or leg bag

  • Check that urine can flow freely

Always follow the manufacturer's instructions supplied with both drainage systems.

Changing the leg bag

The bag should be changed according to the manufacturer's instructions and the user's individual catheter-care plan.

Replace the bag earlier if:

  • Leakage occurs

  • The bag becomes damaged

  • Tubing becomes damaged

  • Drainage becomes impaired

  • The connector becomes contaminated

  • The lever tap no longer closes securely

  • A healthcare professional recommends replacement

Do not continue using a damaged or leaking drainage bag.

Important information:

  • Sterile urinary drainage leg bag

  • Reference DSLB350L

  • 350ml capacity

  • 30cm long tube

  • 180° FLIP-FLO® lever tap

  • Universal ridged connector

  • Needle-free sampling port

  • Designed for daytime urine collection

  • Compact capacity for improved discretion

  • Suitable for appropriate catheter and external urinary drainage systems

  • Suitable for compatible overnight link drainage

  • Keep the bag below bladder level

  • Keep tubing free from kinks and compression

  • Ensure the bag is properly supported

  • Empty the bag before it becomes excessively full

  • Check that the lever tap is completely closed after emptying

  • Maintain appropriate hand hygiene when handling the drainage system

  • Avoid unnecessary disconnection of the drainage system

  • Check the skin beneath straps for pressure or irritation

  • Replace the bag if damaged, leaking or no longer draining correctly

  • Seek appropriate clinical advice if urine unexpectedly stops draining or catheter blockage is suspected

  • Fever, flank pain, significant lower abdominal pain, blood in the urine or other symptoms suggesting urinary infection or catheter complications require appropriate clinical assessment

  • Always follow the manufacturer's instructions and the individual catheter-care plan

Product details:

  • Product: Spirit® Sterile Urine Drainage Leg Bag

  • Manufacturer: Bard Ltd

  • Reference / order code: DSLB350L

  • Capacity: 350ml

  • Tube length: 30cm

  • Tube type: Long tube

  • Tap: 180° FLIP-FLO® lever tap

  • Connector: Universal ridged connector

  • Sampling port: Needle-free

  • Sterile: Yes

  • Application: Daytime urinary drainage

  • Leg mounted: Yes

  • Overnight link drainage compatible: Yes, with an appropriate compatible system

  • Leg straps: Supplied

  • Sterile gloves: Supplied

  • Pack size: 10 leg bags

  • NHS Drug Tariff: Listed

  • Classification: Urinary drainage appliance / medical device

Order code:

  • DSLB350L – Spirit® Sterile Urine Drainage Leg Bag – 350ml – 30cm Long Tube – Lever Tap – Pack of 10

Bard Spirit® DSLB350L combines a compact 350ml sterile drainage bag, 30cm long tube, 180° FLIP-FLO® lever tap, universal ridged connector and needle-free sampling port in a practical leg-mounted urine collection system.

The smaller 350ml capacity provides a discreet option for daytime use, while the 30cm tubing offers additional flexibility for positioning the bag lower on the leg.

Always follow the manufacturer's instructions and the user's individual catheter-care plan.