Ring Pessary PVC

£4.40
10 in stock
Type

Ring Pessary PVC is a soft, flexible vaginal support device used in the management of pelvic organ prolapse, particularly mild to moderate uterine or vaginal prolapse.

The pessary is inserted into the vagina to provide mechanical support to the uterus, vaginal walls and surrounding pelvic organs. It can provide a non-surgical treatment option for people who wish to avoid surgery, are awaiting surgery or are not suitable for surgical treatment.

The pessary must be appropriately sized and initially fitted by a trained healthcare professional.

Key features:

  • Vaginal ring pessary for pelvic organ prolapse
  • Suitable particularly for Stage I and Stage II prolapse
  • Helps support the uterus, vagina, bladder and/or rectum
  • Soft and flexible for easier insertion and patient comfort
  • Made from medical-grade PVC
  • Smooth, rounded design
  • White in colour
  • 12.5mm wall thickness
  • Available in a wide range of diameters from 50mm to 100mm
  • Latex free
  • Metal free
  • Suitable to remain in place during X-ray, CT and MRI examinations
  • Non-sterile
  • Reusable by the same patient only
  • Individually packaged
  • Recommended replacement interval: every 6 months
  • Medical device

Available sizes:

  • Size 0 – 50mm
  • Size 1 – 53mm
  • Size 2 – 56mm
  • Size 3 – 59mm
  • Size 4 – 62mm
  • Size 5 – 65mm
  • Size 6 – 68mm
  • Size 7 – 71mm
  • Size 8 – 74mm
  • Size 9 – 77mm
  • Size 10 – 80mm
  • Size 11 – 85mm
  • Size 12 – 90mm
  • Size 13 – 95mm
  • Size 14 – 100mm

All sizes have a wall thickness of approximately 12.5mm.

Material:

Medical-grade polyvinyl chloride (PVC).

The Balance PVC Ring Pessary is:

  • Latex free
  • Metal free
  • Free from added chemical dyes

How it is used:

The correct size and type of pessary should be selected by a doctor, specialist nurse, pelvic health professional or other appropriately trained healthcare professional.

Correct sizing is important. A pessary that is too small may move or fall out, while one that is too large may cause discomfort, pressure or difficulty passing urine.

After fitting, the patient should be able to:

  • Sit, stand and walk comfortably
  • Pass urine normally
  • Carry out normal daily activities without significant discomfort

The pessary should remain securely positioned without causing excessive pressure.

Some patients may be taught by their healthcare professional to remove, clean and reinsert their own ring pessary. Self-management should only be undertaken after appropriate assessment and training.

Cleaning and care:

If the patient has been advised to remove and clean the pessary:

  • Wash using mild soap and water
  • Rinse thoroughly with clean running water
  • Allow to dry before reinsertion
  • Inspect the pessary for cracks, damage, loss of shape or deterioration

Do not continue using a pessary that is:

  • Cracked
  • Split or damaged
  • Discoloured
  • Misshapen
  • No longer flexible

A new PVC ring pessary should normally be supplied at least every 6 months, or sooner if deterioration is identified.

Important information:

A PVC Ring Pessary is a medical device and should be fitted and monitored by an appropriately trained healthcare professional.

Do not use in the presence of:

  • Pelvic or acute genital tract infection
  • Vaginal or pelvic lacerations
  • Significant untreated vaginal ulceration
  • Known PVC allergy
  • Pregnancy
  • Other conditions where the treating clinician considers pessary use inappropriate

Regular clinical review is important because prolonged pessary use without appropriate monitoring can cause complications including:

  • Vaginal irritation
  • Increased or abnormal vaginal discharge
  • Vaginal bleeding
  • Ulceration or erosion
  • Infection
  • Difficulty passing urine or stool
  • Pessary displacement or expulsion
  • Rarely, impaction or entrapment

Seek medical advice if there is:

  • New or persistent vaginal bleeding
  • Foul-smelling or unusual vaginal discharge
  • Vaginal pain or significant discomfort
  • Difficulty passing urine
  • Difficulty opening the bowels
  • Vaginal itching or irritation
  • Repeated displacement or expulsion of the pessary

Replacement interval:

The manufacturer recommends replacing a PVC Ring Pessary every 6 months at the latest, even where there are no complications.

Replace sooner if there is any cracking, damage, loss of shape or loss of flexibility.

Storage:

Before use, keep the pessary:

  • In its original packaging
  • In a dry, dark place
  • Away from direct sunlight
  • Protected from damage

Do not use if the original packaging is damaged or if the pessary itself appears damaged or abnormal.

Product type: Vaginal Pessary / Pelvic Organ Prolapse Support Device

Material: Medical-grade PVC

Wall thickness: 12.5mm

Colour: White

Latex free: Yes

Metal free: Yes

MRI / CT compatible: Yes

Sterility: Non-sterile

Use: Reusable for one patient only

Recommended replacement: Every 6 months

Pack size: 1 pessary

Sizes and PIP codes:

  • 50mm / Size 0 – PIP 416-6104
  • 53mm / Size 1 – PIP 416-6112
  • 56mm / Size 2 – PIP 416-6187
  • 59mm / Size 3 – PIP 416-6203
  • 62mm / Size 4 – PIP 416-6138
  • 65mm / Size 5 – PIP 416-6146
  • 68mm / Size 6 – PIP 416-6195
  • 71mm / Size 7 – PIP 416-6211
  • 74mm / Size 8 – PIP 416-6229
  • 77mm / Size 9 – PIP 416-6161
  • 80mm / Size 10 – PIP 416-6237
  • 85mm / Size 11 – PIP 416-6179
  • 90mm / Size 12 – PIP 416-6120
  • 95mm / Size 13 – PIP 416-6153
  • 100mm / Size 14 – PIP 416-6245

The correct pessary size and type must be selected by an appropriately trained healthcare professional. Do not select a size solely on the basis of a previous pessary or self-measurement.

You might receive Portia or Balance Pessary PVC rings.

Product Information Leaflet 


 

Ring Pessary PVC is a soft, flexible vaginal support device used in the management of pelvic organ prolapse, particularly mild to moderate uterine or vaginal prolapse.

The pessary is inserted into the vagina to provide mechanical support to the uterus, vaginal walls and surrounding pelvic organs. It can provide a non-surgical treatment option for people who wish to avoid surgery, are awaiting surgery or are not suitable for surgical treatment.

The pessary must be appropriately sized and initially fitted by a trained healthcare professional.

Key features:

  • Vaginal ring pessary for pelvic organ prolapse
  • Suitable particularly for Stage I and Stage II prolapse
  • Helps support the uterus, vagina, bladder and/or rectum
  • Soft and flexible for easier insertion and patient comfort
  • Made from medical-grade PVC
  • Smooth, rounded design
  • White in colour
  • 12.5mm wall thickness
  • Available in a wide range of diameters from 50mm to 100mm
  • Latex free
  • Metal free
  • Suitable to remain in place during X-ray, CT and MRI examinations
  • Non-sterile
  • Reusable by the same patient only
  • Individually packaged
  • Recommended replacement interval: every 6 months
  • Medical device

Available sizes:

  • Size 0 – 50mm
  • Size 1 – 53mm
  • Size 2 – 56mm
  • Size 3 – 59mm
  • Size 4 – 62mm
  • Size 5 – 65mm
  • Size 6 – 68mm
  • Size 7 – 71mm
  • Size 8 – 74mm
  • Size 9 – 77mm
  • Size 10 – 80mm
  • Size 11 – 85mm
  • Size 12 – 90mm
  • Size 13 – 95mm
  • Size 14 – 100mm

All sizes have a wall thickness of approximately 12.5mm.

Material:

Medical-grade polyvinyl chloride (PVC).

The Balance PVC Ring Pessary is:

  • Latex free
  • Metal free
  • Free from added chemical dyes

How it is used:

The correct size and type of pessary should be selected by a doctor, specialist nurse, pelvic health professional or other appropriately trained healthcare professional.

Correct sizing is important. A pessary that is too small may move or fall out, while one that is too large may cause discomfort, pressure or difficulty passing urine.

After fitting, the patient should be able to:

  • Sit, stand and walk comfortably
  • Pass urine normally
  • Carry out normal daily activities without significant discomfort

The pessary should remain securely positioned without causing excessive pressure.

Some patients may be taught by their healthcare professional to remove, clean and reinsert their own ring pessary. Self-management should only be undertaken after appropriate assessment and training.

Cleaning and care:

If the patient has been advised to remove and clean the pessary:

  • Wash using mild soap and water
  • Rinse thoroughly with clean running water
  • Allow to dry before reinsertion
  • Inspect the pessary for cracks, damage, loss of shape or deterioration

Do not continue using a pessary that is:

  • Cracked
  • Split or damaged
  • Discoloured
  • Misshapen
  • No longer flexible

A new PVC ring pessary should normally be supplied at least every 6 months, or sooner if deterioration is identified.

Important information:

A PVC Ring Pessary is a medical device and should be fitted and monitored by an appropriately trained healthcare professional.

Do not use in the presence of:

  • Pelvic or acute genital tract infection
  • Vaginal or pelvic lacerations
  • Significant untreated vaginal ulceration
  • Known PVC allergy
  • Pregnancy
  • Other conditions where the treating clinician considers pessary use inappropriate

Regular clinical review is important because prolonged pessary use without appropriate monitoring can cause complications including:

  • Vaginal irritation
  • Increased or abnormal vaginal discharge
  • Vaginal bleeding
  • Ulceration or erosion
  • Infection
  • Difficulty passing urine or stool
  • Pessary displacement or expulsion
  • Rarely, impaction or entrapment

Seek medical advice if there is:

  • New or persistent vaginal bleeding
  • Foul-smelling or unusual vaginal discharge
  • Vaginal pain or significant discomfort
  • Difficulty passing urine
  • Difficulty opening the bowels
  • Vaginal itching or irritation
  • Repeated displacement or expulsion of the pessary

Replacement interval:

The manufacturer recommends replacing a PVC Ring Pessary every 6 months at the latest, even where there are no complications.

Replace sooner if there is any cracking, damage, loss of shape or loss of flexibility.

Storage:

Before use, keep the pessary:

  • In its original packaging
  • In a dry, dark place
  • Away from direct sunlight
  • Protected from damage

Do not use if the original packaging is damaged or if the pessary itself appears damaged or abnormal.

Product type: Vaginal Pessary / Pelvic Organ Prolapse Support Device

Material: Medical-grade PVC

Wall thickness: 12.5mm

Colour: White

Latex free: Yes

Metal free: Yes

MRI / CT compatible: Yes

Sterility: Non-sterile

Use: Reusable for one patient only

Recommended replacement: Every 6 months

Pack size: 1 pessary

Sizes and PIP codes:

  • 50mm / Size 0 – PIP 416-6104
  • 53mm / Size 1 – PIP 416-6112
  • 56mm / Size 2 – PIP 416-6187
  • 59mm / Size 3 – PIP 416-6203
  • 62mm / Size 4 – PIP 416-6138
  • 65mm / Size 5 – PIP 416-6146
  • 68mm / Size 6 – PIP 416-6195
  • 71mm / Size 7 – PIP 416-6211
  • 74mm / Size 8 – PIP 416-6229
  • 77mm / Size 9 – PIP 416-6161
  • 80mm / Size 10 – PIP 416-6237
  • 85mm / Size 11 – PIP 416-6179
  • 90mm / Size 12 – PIP 416-6120
  • 95mm / Size 13 – PIP 416-6153
  • 100mm / Size 14 – PIP 416-6245

The correct pessary size and type must be selected by an appropriately trained healthcare professional. Do not select a size solely on the basis of a previous pessary or self-measurement.

You might receive Portia or Balance Pessary PVC rings.

Product Information Leaflet